System installation instructions
1
System 0020180635
VWS 36/4.1 230V with gas-fired boiler, 2-zone module, VRC 700 and VR 91
Caution.
Risk of material damage caused by incomplete installation.
This drawing is a basic representation and does not replace complete planning. This drawing does not
contain all of the required valves and safety fittings for a complete installation.
▶
Observe the applicable national and international laws, standards and guidelines.
▶
When planning, installing and subsequently operating this system, you must observe all the install-
ation and operating instructions available for the product, the relevant accessories and for any other
component.
▶
The responsibility for design lies with the responsible company.
1.1
Basic hydraulic diagram 0020180635
1
Heat generator
2
Heat pump
3e
Circulation pump
5
Monovalent domestic hot water cylinder
7i
2-zone module
8a
Expansion relief valve
8b
Potable water expansion relief valve
Safety group – drinking water connection
8c
8e
Heating diaphragm expansion vessel
Diaphragm expansion vessel – potable water
8f
0020251826_01 System installation instructions
System 0020180635 1
9a
Single-room temperature control valve (thermo-
static/motorised)
9b
Zone valve
9c
Flow regulator valve
9d
Bypass valve
9h
Filling/draining cock
9j
Tamper-proof capped valve
9k
3-port mixing valve
10c
Non-return valve
12
System control
12a
Remote control unit
1