System Installation Instructions - Vaillant 0020232108 Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27

System installation instructions

1
System 0020232108
VWS 36/4.1 230V with VIH QW/1 E and VRC 700
Caution.
Risk of material damage caused by incomplete installation.
This drawing is a basic representation and does not replace complete planning. This drawing does not
contain all of the required valves and safety fittings for a complete installation.
Observe the applicable national and international laws, standards and guidelines.
When planning, installing and subsequently operating this system, you must observe all the install-
ation and operating instructions available for the product, the relevant accessories and for any other
component.
The responsibility for design lies with the responsible company.
1.1
Basic hydraulic diagram 0020232108
2
Heat pump
3e
Circulation pump
5e
Hydraulic tower
8b
Potable water expansion relief valve
Safety group – drinking water connection
8c
8e
Heating diaphragm expansion vessel
0020251824_01 System installation instructions
System 0020232108 1
Diaphragm expansion vessel – potable water
8f
9a
Single-room temperature control valve (thermo-
static/motorised)
9d
Bypass valve
9h
Filling/draining cock
9j
Tamper-proof capped valve
1

Publicité

Table des Matières
loading

Table des Matières