section 1. important safety instructions
READ AnD FOllOW All insTRuCTiOns
This device can only be used in swimming pools and swimming pools with a built-in spa. It cannot be used in stand-
alone spas.
All electrical work must be performed by a licensed electrician and conform to all national, provincial, and local
codes. When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
EQuiPMEnT unDER PREssuRE: Always turn pump off prior to installing or servicing the power pack or cell.
Your pump/filter system is operated under pressure and the pressure must be released before you begin work.
Please see your pump/filter owner's manual for further instructions.
Zodiac AquaPure Ei Series APURE35C chlorine generating devices are designed for domestic (residential)
swimming pool use only. Contrary use could affect performance, void warranty, and may result in property damage,
serious injury, or death.
• Heavy pool (or spa) usage and higher temperatures may require higher chlorine output to maintain proper free
available chlorine/bromine residuals.
• Operating a chlorine generator without water flowing through the cell may cause a build up of flammable
gases, resulting in fire or explosion.
• To reduce the risk of injury, do not permit children to operate this device.
• A damaged supply cord should only be replaced by the manufacturer, service agent or electrician.
• When installing and using this electrical equipment, always follow basic safety precautions.
• Before performing installation, disconnect all power.
• Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI).
• Do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
Installation must be done in accordance with the Canadian Electrical Code
and national installation codes.
RisK OF ElECTRiC shOCK, FiRE, PERsOnAl inJuRY, OR DEATh. Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the
circuit is protected by a GFCI. Make sure such a GFCI should be provided by the installer and should be tested on
a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button.
Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts
power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility
of electrical shock. Do not use the device. Disconnect the device and have the problem corrected by a qualified
service representative before using.
A wire-binding screw for grounding (labeled
shock, connect the ground wire to the grounding points in the power pack and of your electric service or supply
panel with a conductor equivalent in size to the circuit conductors supplying this equipment.
The power pack must be interlocked/interconnected with the pool pump motor power source to ensure that the
chlorinator only operates when the pool pump is operating.
AquaPure
Ei Series APURE35C
®
) is provided inside the power pack. To reduce risk of electric
|
Installation and Operation Manual
WARning
WARning
WARning
®
English
(CEC
or C22.1) and/or any other local
®
Page 5