important safety instructions
READ AnD FOllOW All insTRuCTiOns
This device can only be used in swimming pools and swimming pools with a built-in spa. It cannot be used in stand-
alone spas.
All electrical work must be performed by a licensed electrician and conform to all national, provincial, and local
codes. When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
EQuiPMEnT unDER PREssuRE: Always turn pump off prior to installing or servicing the power pack or cell.
Your pump/filter system is operated under pressure and the pressure must be released before you begin work.
Please see your pump/filter owner's manual for further instructions.
To reduce the risk of electric shock, fire or injury, service should only be attempted by a qualified pool service professional.
Zodiac AquaPure Ei Series APURE35PLGC chlorine generating devices are designed for domestic (residential)
swimming pool use only. Contrary use could affect performance, void warranty, and may result in property damage,
serious injury, or death.
• Heavy pool (or spa) usage and higher temperatures may require higher chlorine output to maintain proper free
available chlorine/bromine residuals.
• Operating a chlorine generator without water flowing through the cell may cause a build up of flammable
gases, resulting in fire or explosion.
• To reduce the risk of injury, do not permit children to operate this device.
• A damaged supply cord should only be replaced by the manufacturer, service agent or electrician.
• When installing and using this electrical equipment, always follow basic safety precautions.
• Before performing installation, disconnect all power.
• Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI).
• Do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
• The power pack must be be installed at least 1.5 m (5 ft.) vertically off the ground.
• The power pack must be be installed at least 3 m (10 ft.) from the inside wall of your swimming pool or built-in
spa
Should a lack of water be detected, the unit's electronic flow switch is designed to turn off the system. Interfering
with the electronic flow switch could result in personal injury and/or damage to the cell.
Operating the Zodiac AquaPure Ei Series APURE35PLGC chlorine generating device without water lfow through
the electrolytic cell can cause a buildup of flammable gasses which can result in FIRE or EXPLOSION.
|
Ei Series APURE35PLGC
Installation and Operation Manual
®
WARning
WARning
WARning
WARning
WARning
WARning