6.3
Cleaning the Cell
WARning
Disconnect power to the system at the main circuit
breaker before performing this procedure to avoid risk
of electric shock which can result in property damage,
severe injury or death.
WARning
• When cleaning the cell, wear protective eyeglasses
and gloves.
• When mixing acid with water, AlWAYs ADD ACiD
TO WATER. nEVER ADD WATER TO ACiD.
The power pack has an automatic cell cleaning feature
(polarity reversing) that removes scale deposits from the
cell (see Section 5.6).
Scale will form in excessively hard water or from pool
water that is out of balance and in a scaling condition.
Following the installation of the Zodiac AquaPure Ei
Series APURE35C chlorine generating device, check
the cell once a month for signs of scale.
If the cell has a tendency to scale, it is recommended
that every month the cell be removed and inspected for
scale formation and/or debris. Some filters allow debris
to pass through to the cell which could lodge between
the plates in the cell. A small amount of scale formation
is normal. If by looking through the cell it is observed
that there is excessive scale formation between the
plates or debris is present, the cell must be cleaned as
follows:
1.
Ensure that all power to the power pack and
the controller is disconnected/turned off at the
circuit breaker.
2.
Before removing the cell for cleaning, shut off
any necessary valves to prevent any water loss.
3.
Open the air relief valve to release any pressure
in the pool system.
4.
Remove the terminal cap and cell leads.
5.
Undo the locking ring. If required, use the
locking ring tool provided (see Figure 25).
Zodiac
AquaPure
Ei Series APURE35C
®
®
Figure 25. undo locking Ring
6.
Figure 26. Remove the Cell
7.
Figure 27. invert the Cell
|
Installation and Operation Manual
Remove the cell (see Figure 26).
Refit the cap on the cell and invert
(see Figure 27).
Locking Ring
Tool