3.8
split Return Plumbing instructions
For Infloor Cleaning Systems
If the chlorinator is used with an in-floor cleaning
system, it must be installed in a separate dedicated
return line or damage to the chlorinator will occur.
nOTE Do not install the chlorinator on in-floor systems that
do not have a dedicated pool return as shown in
Figure 22.
Cell
* The cell must be
installed as the last
piece of equipment in
the circulation plumbing
system just before
the pool.
Control Valve Installation Options
Install between
the inlet and
discharge
side of bypass
plumbing
Figure 21. Example of Bypass installation
Zodiac
AquaPure
®
Heater
Install on
the inlet side
of the vessel
Pool Return
|
Ei Series APURE35C
Installation and Operation Manual
®
Power Pack
Filter
To common
power source
Pump
Pool Intake
Spa Return
Spa Intake