Pentair MasterTemp Notice D'utilisation page 22

Chauffe-piscine/spa c.a. 120/240 volts au gaz naturel/gpl. 200k btu/h, 250k btu/h, 300k btu/h, 400k btu/h
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Reinstall the access door panels.
The fuse for the Fireman's Switch is a 1.25 amp
1-1/4x1/4" fast blow fuse, available locally.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the Door Panels (see Figure 3,
Page 5).
2. Access the control panel board on the underside of
the top cover. Locate the red button on the corner of
the control board (see Figure 24).
3. Push the Max. Temp. Set Point button on the back of
the control board (see Figure 24).
The following sequence should happen:
A. The unit will come on and the POOL ON light will
come on.
▲ ▲
B. Press the
TEMP or
the panel) to set maximum pool temperature.
C. Wait up to 30 seconds; the POOL ON light will go
FIGURE 24: Max Temperature Set Point Controls
off and the SPA ON light will come on. To override
the time delay, push the Max. Temp. Set Point
button again.
▲ ▲
D. Press the
TEMP or
control panel and set maximum spa temperature
to 104°F (40°C) or less.
E. Wait up to 30 seconds; the SPA ON light will go
off and the unit will shut down. To override the
time delay, push the Max. Temp. Set Point button
again.
4. Reinstall the access door panels.
▼ ▼
TEMP pad (on TOP of
▼ ▼
TEMP button on the
22

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

460730460731460732460733460734460735 ... Afficher tout

Table des Matières