Compression Load Cell S-Type PR 6241
Designation
Minimum dead load
Maximum capacity
Safe load limit
Destructive load
Minimum LC veriica-
tion
Minimum preload sig-
nal recurrence
Rated output
Tolerance on rated
output
Zero output signal
Repeatability
Creep
Non-linearity
Hysteresis
Temperature efect
on Smin
Temperature efect
on C
Input impedance
Output impedance
Insulation impedance between measuring circuit and
Insulation voltage
Recommended sup-
ply voltage
Max. supply voltage
Minebea Intec
Description
lowest limit of speciied measu-
ring range
highest limit of speciied mea-
suring range
maximum load without irrever-
sible damage
danger of mechanical destructi-
on
minimum load cell scale inter-
val, v
= E
/Y
min
max
recurrence of the minimum pre-
load signal (DR = ½×E
max
relative output at maximum ca-
pacity
permissible deviation from ra-
ted output C
n
load cell output signal under un-
loaded condition
max. change in load cell output
for repeated loading
max. change of output signal at
E
during 30 minutes
max
deviation from best straight line
through zero
max. diference in LC output
between loading and unloading
max. change of S
per 10 K in
min
B
T
max. change of C per 10 K in B
between supply terminals
between measuring terminals
housing at 100 V DC
between circuit and housing
(PR 6241/..E only)
to hold the speciied perfor-
mance
permissible for continuous ope-
ration without damage
Abbr. D1
E
0
min
E
See Chapter
max
E
150
lim
E
>300
d
Y
5000
Z
1000
/Z)
C
2
n
d
<0.25
c
S
<1.0
min
<0.01
R
ɛ
d
<0.03
cr
d
<0.03
Lin
d
<0.04
hy
TK
<0.028
Smin
TK
<0.03
T
C
R
650 ±6
LC
R
610 ±1
O
R
>5000
IS
500
B
4
24
u
U
28
max
4 Speciications
C3
C6
Unit
0
0
% E
4.5
150
150
% E
>300
>300
% E
14000
20000
3000
8000
2
2
mV/V
<0.07
<0.07
% C
<1.0
<1.0
% C
<0.005
<0.005
% C
<0.015
<0.008
% C
<0.01
<0.01
% C
<0.015
<0.008
% C
<0.01
<0.007
% C
<0.01
<0.005
% C
650 ±6
650 ±6
Ω
610 ±0.5 610 ±0.5 Ω
>5000
>5000
MΩ
500
500
V
4
24
4
24
V
28
28
V
max
max
max
n
n
n
n
n
n
/10 K
n
/10 K
n
EN-12