6. SPECIFICATIONS

Features
AT-6010-R
Measurement
CAT III 600 V
Category
Operating
0 to 600 V AC/DC
Voltage
Operating
Energized: 6.25 kHz
Frequency
De-Energized: 32.768 kHz
Hazardous
N/A
Voltage Detection
Signal Indications Numeric bar graph display
and audible beep
Response Time
Tip Sensor (Energized /
De-energized): 500 ms
Battery voltage monitoring:
5 sec
Current Output of
N/A
Signal (typical)
Signal Voltage
N/A
Output (nominal)
Range Detection
Tip Sensor (Energized):
Max distance via air:
(open air)
up to 20 ft (6.1 m)
Pinpointing:
approx. 1.97 in (5 cm)
Tip Sensor (De-energized):
Max distance via air:
up to 14.7 ft (4.5 m)
Pinpointing:
approx. 1.97 in (5 cm)
AT-6010-T
CAT III 600 V
0 to 600 V AC/DC
Energized: 6.25 kHz
De-Energized: 32.768 kHz
> 30 V AC/DC
LEDs
Line voltage monitoring:
1 sec
Battery voltage monitoring:
5 sec
Energized circuit:
HI mode: 60 mA RMS
De-energized circuit:
HI mode: 130 mA RMS
Loop mode: 160 mA RMS
De-energized circuit:
HIGH: 33 V RMS, 140 Vp-p
With CT-400:
Loop model:
31 V RMS, 120 Vp-p
N/A
25
CT-400
CAT IV 600 V,
CAT III 1000 V
0 to 1000 V AC
Wire tracing: 32.768 kHz
AC current measurement:
45 Hz to 400 Hz
N/A
N/A
Instantaneous
1 mA/A for AC current
measurement with
multimeter
De-energized circuit:
2.4 V RMS, 24 Vp-p
N/A