Configuring Settings; Switching On The Vacuum Cleaner - Starmix ISC CLDC Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38

5.2 Configuring settings

5.2.1 Set filter cleaning mode*
The vacuum cleaner is equipped with an electromagnetic filter
cleaning system that shakes off any dust clinging to the pleated
filter cassettes.
Filter cleaning takes place automatically in the next work break
when the set minimum volume flow is reached (switch position
>AUTO<).
Set the desired mode on the filter cleaning rotating switch (see
chKap. 3 „Display and control elements" on page 27).
Information on manual cleaning can be found in chapter 5.4.3.
5.2.2 Set hose diameter *
l CAUTION!
Preselector switch for minimum volume flow signal (horn
and light for dust class "M" vacuum cleaners)
If the incorrect hose diameter is set, the warning function will not
work as intended when the suction power decreases.
Set the hose diameter correctly.
For class M vacuum cleaners, set the hose diameter with the
switch:
Preselector switch for
inner hose diameter
∅ 35 mm
∅ 32 mm
∅ 27 mm
∅ 21 mm
∅ 15 mm

5.3 Switching on the vacuum cleaner

The vacuum cleaner is switched on using the control dial for
operating mode / speed.
Two operating modes are available in which the suction power can
be regulated in 3 stages:
Set the control dial to the desired speed level in the >ON<
range.
The vacuum cleaner starts up immediately.
or:
Set the control dial to the desired speed level in the >AUTO<
range.
The vacuum cleaner is in standby mode for power tools
(only in conjunction with cordless control*)
30 - en
5.4 Vacuuming
Risk of fire! Explosion hazard! Risk of electric shock!
5.4.1 Dry vacuuming
Class M vacuum cleaners should preferably be used as dry
vacuum cleaners.
5.4.2 Wet vacuuming
Risk of electric shock!
Flow rate
69 m³/h
58 m³/h
1
41 m³/h
25 m³/h
13 m³/h
If the vacuum cleaner is not switched off, the restart protection
remains effective. The vacuum cleaner is only ready for operation
again after it has been switched off and back on again.
l WARNING!
Observe the safety instructions in chapter 2.
Only vacuum with a dry filter, vacuum cleaner and accessories
to prevent dust from sticking and becoming encrusted.
For vacuuming soot, cement, plaster or similar dust: Insert the
PE emptying bag into the dust container.
Always use filter bags in conjunction with pleated filter
cassettes.
NOTE
l WARNING!
If foam or liquid is leaking out, switch off the vacuum cleaner
immediately. Empty the container and pleated filter cassette.
NOTE
Clean the water level sensors (1) and
check for signs of damage regularly.
1
Vacuum without a non-woven filter bag.
The pleated filter cassettes are suitable for wet vacuuming.
The built-in sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be impaired by a
full container.
Empty the container (see chKap. 5.5 „Removing the vacuumed
material" on page 31).
NOTE
Before emptying, first remove the suction hose from the liquid.
Due to the high suction power and streamlined container shape,
some water may run back out of the hose after switching off.
Use dry filters for subsequent dry vacuuming.
* depending on equipment variant

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Isc batrix l 36-18vIsc batrix m 36-18v

Table des Matières