Operating Elements And Connections; Safety Notes; Applications - IMG STAGELINE PARL-40DMX Mode D'emploi

Masquer les pouces Voir aussi pour PARL-40DMX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
All operating elements and connections de -
GB
scribed can be found on the fold-out page 3.
1 Operating Elements
and Connections
1 Mounting /set-up brackets
2 Display
3 Locking screws for the mounting /set-up brack-
ets
4 Microphone for music control
5 XLR chassis mount plug DMX IN: DMX signal
input for connection of a light controller or to the
DMX signal output of another spotlight
6 XLR jack DMX OUT: DMX signal output for con-
nection to the DMX input of another DMX-con-
trolled unit
7 Buttons to select the operating mode and to
change adjustments
8 Mains cable for connection to a socket (230 V~/
50 Hz)

2 Safety Notes

The unit corresponds to all relevant directives of
the EU and is therefore marked with
WARNING The unit uses hazardous mains volt-
age. Leave servicing to skilled per-
sonnel only and do not insert any-
thing into the air vents; inexpert
handling may result in electric shock.
Please observe the following items in any case:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient tempera-
ture range 0 – 40 °C).
G
Do not operate the unit or immediately discon-
nect the mains plug from the mains socket
1. if the unit or the mains cable is visibly dam-
aged,
2. if a defect might have occurred after the unit
was dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled
personnel.
G
A damaged mains cable must only be replaced
by skilled personnel.
G
Never pull the mains cable for disconnecting the
mains plug from the socket, always seize the
plug.
10
G
For cleaning only use a dry, soft cloth, never use
chemicals or water.
G
No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is not
safely mounted, not correctly connected or oper-
ated, or if it is not repaired in an expert way.
G
Important for U. K. Customers!
The wires in this mains lead are coloured in ac -
cord ance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol , or coloured green or green and yel-
low.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
.
letter L or coloured red.
Warning – This appliance must be earthed.

3 Applications

This LED spotlight serves for illumination e. g. on
stage, in discotheques, and festival rooms. As a
light source, four extra bright LEDs are used. The
spotlight is designed for control via a DMX light
controller (8, 6, 5, 4 or 3 DMX control channels
available). However, it can also be operated inde-
pendently.
As a special feature for DMX operation the
PARL-40DMX offers the use of 66 sub-addresses.
Thus, it is possible to control up to 66 spotlights
(spotlight groups) via a single DMX start address
independently of each other and the maximum
number of DMX-controlled units is considerably
increased.
If the unit is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment.