1. GENERAL INSTRUCTION
The heaters mentioned in this maintenance leaflet must only be used outdoors or in well ventilated
surroundings.
For every kW it is necessary to have permanent ventilation of 25 cm
and high level, with a minimum outlet of 250 cm
Gas cylinders must be used and kept in accordance with current regulations.
Never direct the hot air flow towards the cylinder.
Use only the supplied pressure regulator.
Never use the heater without its cover.
Do not exceed 100 W/m
Do not obstruct the inlet or outlet sections of the heater.
If the heater has to work for a long period at its maximum capacity, it is possible that ice will form on the
cylinder.This is due to excessive vapour withdrawal. Not for this reason, or for any other, should the cylinder
be heated. To avoid this effect, or at least to reduce it, use a large cylinder or two cylinders linked together
(Fig.1).
Do not use the heater in cellars, basements or in any room below the ground level.
In case of malfunction, please contact the technical assistance service.
The heater must be isolated from the gas bottle by means of a valve.
The gas bottle must always be replaced following safety rules away from any possible source of ignition.
The gas hose must not be twisted or bent.
The heater must be placed where there is no
risk of fire, the hot air outlet must be at least
3 m from any flamable wall or ceiling and must
never be directed towards the gas bottle.
Only use original gas hose and spare parts.
Heaters described in this leaflet are not
intended for domestic use.
In the case that a gas leak is found or
suspected, immediately close the gas cylinder,
switch the heater off and do not use it again
until it has been checked by a qualified service centre. If the heater is installed inside, provide a good ventila-
tion by opening door and windows completely. Do not produce sparks or free flames.
If in any doubt contact your supplier.
2. INSTALLATION
Connect the heater to a suitable electric socket (230 V ~ 50 Hz or 110 V ~ 50 Hz for dual voltage U.K. units).
Make sure that the machine is properly cylinder.
Connect the gas supply hose to the pressure regulator and connect the regulator to a suitable LPG cylinder.
Open the tap of the cylinder and check the supply hose and fittings for leak detector gas leaks. For this
operation it is recommended to use an approved.
NEVER USE NAKED FLAME.
For automatic appliances, connect the room thermostat to the socket on the appliance and adjust it to the
required temperature.
3. INSTRUCTIONS FOR USE
3.1 IGNITION

Manual ignition

Turn the fan switch to position I and check that the fan starts running correctly. (Fig. 2)
Push the gas valve button and push repeatedly the piezoelectric lighter until the flame lights up. (Fig. 3-4)
As the flame lights up, keep the valve button pushed for 10 seconds approx. (Fig.5). Should the heater stop
when the valve button has been released, wait one minute and repeat the starting operation keeping the valve
button pushed for a longer time.
Regulate the gas flow pressure according to the desired heat output, by turning the wheel of the pressure
reducer anticlockwise to increase the pressure or clockwise to decrease.
GB
2
2
.
3
of free room.The minimum volume of the room must be greater than 100 m
2
, equally distributed between the floor
3
.
Fig. 1