12
GB
FACTORY SETTING
STEP NO. DESCRIPTION
1
Air flow rate mode
/
2
Air flow rate mode 1 /
3
Air flow rate mode 2 /
4
Air flow rate mode 3 /
5
Bypass temperature
6
Bypass hysterese
7
Operation bypass valve
Central heating +
8
heat recovery
9
Imbalance permissible
10
Fixed imbalance
FACTORY SETTING
STEP NO. DESCRIPTION
Ubiflux F200 PLUS
11
Heater
12
Temperature postheater
13
Selection input 1
14
Minimum voltage input 1
15
Maximum voltage input 1
Conditions
16
switching input 1
Supply fan mode
17
switching input 1
Extract fan mode
18
switching input 1
118
Ubiflux F150(+) - F200(+) - F300(+)
Instelwaarden/ Setting values/ Einstellwerte
Valeurs de réglage
ADJUSTING RANGE
Ubiflux F200
50 m
/h
0 m
/h or 50 m
/h
3
3
3
100 m
/h
50 m
/h - 200 m
/h
3
3
3
125 m
/h
50 m
/h - 200 m
/h
3
3
3
150 m
/h
50 m
/h - 200 m
/h
3
3
3
22,0 °C
15,0 °C - 35,0 °C
2,0 °C
0,0 °C - 5,0 °C
0 (= Automatic)
0
1 (= Bypass valve closed)
2 (= Bypass valve open)
ON (= Central heating+heat recovery on)
OFF
OFF (= Central heating+heat recovery off)
ON (= flow rate supply equals extract)
ON
OFF (= imbalance permissible)
0 m
/h
-100 m
/h - 100 m
/h
3
3
3
ADJUSTING RANGE
0 (= no additional heater)
0
1 (= additional preheater)
2 (= postheater)
21,0 °C
15,0 °C - 30,0 °C
0 (= normally open contact)
1 (= 0 - 10V input active)
2 (= normally closed contact)
0
3 (= input 1/ bypas open 12V;
bypass closed 0V)
4 (= input 1/ bypas open 0V;
bypass closed 12V)
0,0 V
0 Volt - 10 Volt
10,0 V
0 Volt - 10 Volt
0 (= off)
1 (= on)
0
2 (= On if conditions bypass open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
0 (= input fan off))
1 (= Absolute min. flow rate 50m
3
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
5
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No input fan activation)
0 (= exctract fan off)
1 (= Absolute min. flow rate 50m
3
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
5
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No extract fan activation)
Instelwaarden/ Setting values/ Einstellwerte
Valeurs de réglage
STEP
STEP NO. DESCRIPTION
5 m
/h
3
19
Selection input 2
5 m
/h
3
5 m
/h
3
0,5 °C
20
Minimum voltage input 2
0,5 °C
21
Maximum voltage input 2
Conditions
22
switching input 2
1 m
/h
3
Supply fan mode
STEP
23
switching input 2
0,5 °C
Extract fan mode
24
switching input 2
0,5 V
25
Geo heat exchanger
0,5 V
Minimum temperature
geo heat exchanger
26
(Below this temperature
the valve opens.)
Maximum temperature
geo heat exchanger
27
(Above this temperature
/h)
the valve opens.)
STEP NO. DESCRIPTION
28
RH-sensor
/h)
Sensitivity
29
RH-sensor
FACTORY SETTING
ADJUSTING RANGE
Ubiflux F200 PLUS
0 (= normally open contact)
1 (= 0 - 10V input active)
2 (= normally closed contact)
1
3 (= input 2/ bypas open 12V;
bypass closed 0V)
4 (= input 2/ bypas open 0V;
bypass closed 12V)
0,0 V
0,0 Volt - 10,0 Volt
10,0 V
0,0 Volt- 10,0 Volt
0 (= off)
1 (= on)
0
2 (= On if conditions bypass open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
0 (= input fan off))
1 (= Absolute min. flow rate 50m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
5
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No input fan activation)
0 (= extract fan off)
1 (= Absolute min. flow rate 30m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
5
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No extract fan activation)
OFF (= Valve control geo heat exchanger off)
OFF
ON (= Valve control geo heat exchanger on)
5,0 °C
0,0 °C - 10,0 °C
25,0 °C
15,0 °C - 40,0 °C
FACTORY SETTING
ADJUSTING RANGE
Ubiflux F200
UIT (= RH-sensor not active)
OFF
AAN (= RH-sensor active)
+2 most sensitive
+1
↑
0
0 default setting RH-sensor
-1
↓
-2 least sensitive
Ubiflux F150(+) - F200(+) - F300(+)
12
GB
STEP
0,5 V
0,5 V
/h)
3
3
/h)
0,5 °C
0,5 °C
STEP
119