Operation
Changing Switch Position During
Automatic Operation
If the toggle switch is moved to OFF before the water
inlet valve energizes or the water pump starts (45
seconds into the cycle) and is then switched to:
ICE
A normal ice making sequence begins.
CLEAN
A manual clean sequence begins.
(See "Manual Start Operation")
If the toggle switch is moved to OFF after the water inlet
valve energizes (more than 45 seconds into the cycle)
and is then switched to:
ICE
The clean sequence resumes from the
point of interruption. After completion of the
cleaning sequence, the counter resets and
the ice machine starts making ice.
CLEAN
The clean sequence resumes from the
point of interruption.
After completion of the 10-minute wash and
6 rinse cycles, the counter resets and the
ice machine awaits a change in the toggle
switch position.
After 45 seconds, the ice machine will complete the
clean sequence regardless of toggle switch position.
14

Removal from Service/Winterization

! Caution
Leaving solutions in the AuCS® in freezing
temperatures may result in severe damage to the
dispensing pump. A failure of this nature is not
covered by the warranty.
If the AuCS® is to be removed from service for extended
periods, or if it is to be exposed to ambient temperatures
32°F (0°C) or below, follow this procedure:
1. Remove the Cleaning or Sanitizing solution bottle.
2. Follow the instructions under "Hose Priming" to
pump all of the solution out of the dispensing pump
and line.