Section 3

Setting Frequency of Cleanings

The AuCS® is factory-set to initiate and complete a
clean sequence approximately once every two weeks.
For less frequent cleaning, set the selector switch as
indicated below. Refer to "Component Identification" for
selector switch location.
Switch Position
0
1
2
3
NOTE: Switch position 4-9 are inoperative. Do not use
them.
Important
Using the AuCS® accessory is supplemental to
regular cleaning and sanitizing. The AuCS®
accessory will clean surfaces that come in contact
with
the
water
distribution
maintenance must be performed every six months
that includes sanitizing the ice machine, bin (or
dispenser) and adjacent surface areas, which
cannot be contacted by the water distribution
system. Refer to the ice machine installation use
and care manual for cleaning/sanitizing procedures.
!
Read and understand this entire manual prior to
operation of the AuCS®. You must understand all
warning and caution statements and follow all safety
precautions to assure proper operation of your
AuCS® accessory.
Part Number 000007647 06/11
Time Between Cleanings
No cleaning (OFF)
Approximately 2 weeks
(1120 harvests)
Approximately 4 weeks
(2240 harvests)
Approximately 12 weeks
(6720 harvests)
system.
Periodic
Warning
Installing/Replacing Cleaner or Sanitizer
Bottles
! Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
AUCS®-SI
1. Remove right front door from ice machine.
2. Place toggle switch in the OFF position.
3. Disconnect tubing from bottle, then remove bottle.
4. Remove bottle cap and foil seal from new bottle,
then replace bottle cap.
5. Cut 1/4" (6 mm) off end of bottle and reconnect
tubing.
6. Place toggle switch in ice position and reinstall ice
machine door.
Trim End of Bottle,
Then Connect To
Tubing
Remove Cap and Foil
Seal, Then Replace Cap
AUCS®-SO
1. Remove left panel from AuCS®-SO.
2. Unscrew nozzle/tubing from bottle, then remove
bottle.
3. Remove bottle cap and foil seal from new bottle.
4. Install nozzle/tubing on new bottle.