COMMISSIONING
Make sure all monitoring devices are connected
and have been tested.
ELECTRICAL hazard!
Electrical current can cause fatal injuries if not
handled correctly! All connections must be
made by a qualified electrician!
6.2 Rotation direction monitoring
Rotation is controlled via the frequency converter.
• The pump with built-in frequency converter
(TWU 3-...-HS-I) automatically turns in the right
direction.
• In the version with an external frequency con-
verter (TWU 3-...-HS-ECP), the direction of rota-
tion is shown on the display and can be adjusted
from the menu. See "Setting the operating
parameters".
6.3 Operation and function (TWU 3-...-HS-ECP)
Once all the installation work is complete, the
operating parameters have to be adjusted on the
frequency converter.
These adjustments are only possible in the
"ECP" version. In the "I" version with an internal
frequency converter, no further adjustments are
possible.
Overview of functions
• Constant pressure at the tap
• Soft start and stop to reduce pressure surges
• Dry-running protection in the event of low water
in the inlet
• Automatic reset of the dry-running protection
after a specified time
• Leak monitoring
• Rotation direction monitoring and switching of
rotation direction
• Additional connection for functional extension
Installation and operating instructions Wilo-Sub TWU 3-...-HS (High Speed)
Fig. 6: Operating elements
1
4
3
ON/OFF
RESET
2
• Display (1)
• Green LED (2) mains voltage:
The green LED lights up if the power has been
connected correctly. If the power connection is
faulty, the LED does not light up.
• Red LED (3) error message:
The red LED lights up if an error occurs. Consult
the error list to see what error has occurred.
• Yellow LED (4) pump operating status:
The yellow LED indicates the pump's operating
status. If the LED is lit, the pump is running. If the
LED is off, the pump is in standby mode.
•
"ON-OFF/Reset" button: changes from
ON/OFF
RESET
standby (OFF) to operation (ON); resets alarm and
error messages
•
"+" button: increases the displayed value
•
"-" button: reduces the displayed value
•
"»" button: scrolls forward through the menu
•
"«" button: scrolls backward through the
menu
6.3.1 Main menu
All parameters are shown via the display on the
frequency converter. You can use the button be-
neath the display for menu control and to change
the values.
Fig. 7: Main menu
Display during normal
operation
1
Display during standby
mode
2
Voltage and current
3
The parameters can be displayed in standby mode
and during operation. Use the "»" or "«" arrow
keys to switch between individual parameters.
Internal temperatures
4
User language
5
English