GENERAL NOTES
The wires in the mains lead on this appliance are coloured in accordance with the fol-
lowing code:
Green and Yellow - Earth
Blue – Neutral
Brown – Live
As the colours may not correspond with the markings identifying the terminals in your
plug or in your spur box, proceed as follows:
The green and yellow wire must be connected to the terminal which is marked with
the letter E or with the earth symbol
The blue wire must be connected to the terminal marked N or coloured black.
The brown wire must be connected to the terminal marked L or coloured red.
The power supply cord must not touch against any hot surfaces and must be placed so
that its temperature does not exceed 75°C at any point along its length.
After having installed the appliance, the power switch or power plug must always be in
a accessible position.
The appliance must have its own supply; any other appliances installed near it must be
supplied separately.
N.B. For connections to the mains power supply, never use adaptors, reductions or mul-
tiple power points as these may overheat and catch fire.
In the event that installation should require modifications to the mains supply wiring
system or if the power plug is not suitable for the type of power point available, it is
recommended that a qualified technician be called to carry out substitution. The techni-
cian will also have to verify that the cross-section of the electric cables on the power
point match the appliance's power rating.
FEEDER SPECIAL CABLE SECTION
Type "HO5V2V2-F"
resistance to temperatures of 90°C
230 VAC 50 Hz
230 VAC 50 Hz
(for models with a rating of 1,5 kW at 230 V)
The supply cable must be replaced with a cable of the same type.
The electrical cable must be connected to the terminal board following the diagrams
of Fig. 6.3.
or coloured green and yellow.
2
3 x 0,75 mm
2
3 x 1 mm
230 V
L1
PE
N(L
)
2
Fig. 6.3
31