IGNITION MODULE

Before calling your service agent, the following checklist should
be examined to eliminate obvious problems from those requiring
replacement or servicing.
• Check that "main manual gas shut-off valve" is fully open
and that gas service has not been interrupted.
• Check that after following the water OPERATING
INSTRUCTIONS, the "Top Knob" of the gas control valve
is in "ON" position.
Green LED
Indicates
Flash Code
a
OFF
No "Call for Heat"
Flash Fast
Power up - internal check
Heartbeat
Norma l startup – ignition
sequence started (including
prepurge)
4 Seconds
Device in run mode. "x" = flame
ON then "x"
current to the nearest μ A.
flashes
2
5 minute Retry Delay - Pilot flame
not detected during trial for ignition
3
Recycle - Flame failed during run
4
Flame sensed out of sequence
6
Control Internal Error
7
Flame rod shorted to ground
8
Low secondary voltage supply
Flash Code Descriptions:
a
- Flash Fast: rapid blinking.
- Heartbeat: Constant ½ second bright, ½ second dim cycles.
- 4 second solid on pulse followed by "x" 1 second flashes indicates flame current to the nearest μ A. This is only available in run mode.
- A single flash code number signifies that the LED flashes X times at 2H z, remains off for two seconds, and then repeats the sequence.

FLUE DAMPER

Do not turn damper open manually or motor damage will result,
use the service switch. All readings are taken from harness

TROUBLESHOOTING

• Check electrical supply to the water heater for possible
blown (or tripped) fusing or power interruption.
• Is the water temperature in tank below the thermostat dial
setting on the thermostat (calling for heat)?
• It is possible that the high limit (E.C.O.) has functioned to shut
off the water heater. See FEATURES - Water Temperature
Control for reset procedure. Contact your serviceman if limit
continues to function to shut off water heater.
Next System Action
Not applicable
Not applicable
Not applicable
Not applicable
Initiate new trial for ignition after
retry delay completed.
Initiate new trial for ignition. Flash
code will remain through the
ignition trial until flame is proved.
If situation self corrects within 10
seconds, control returns to normal
sequence. If flam e out of
sequence remains longer than 10
seconds, control will resume
normal operation 1 hour after error
is corrected.
Control remains in wait mode.
When the fault corrects, control
resumes normal operation.
Control remains in wait mode.
When the fault corrects, control
resumes normal operation.
Control remains in wait mo de.
When the fault corrects, control
resumes normal operation.
receptacle. Do not push meter leads into harness receptacle.
This opens the pins and will create connection problems. See
the following EFFIKAL RVGP-KSF-SERIES FLUE DAMPER
TROUBLE SHOOTING GUIDE.
36
Recommended Service Action
None
None
None
None
If system fails to light on next trial
for ignition check gas supply, pilot
burner, spark and flame sense
wiring, flame rod contaminated or
out of position, burner ground
connection.
If system fails to light on next trial
for ignition, check gas supply, pilot
burner, flame sense wiring,
contamination of flame rod, burner
ground connection.
Check for pilot flame. Replace gas
valve if pilot flame present. If no
pilot flame, cycle "Call for Heat." If
error repeats, replace con trol.
Cycle "Call for Heat". If error
repeats, replace control.
Check flame sense lead wire for
damage or shorting. Check that
flame rod is in proper position.
Check flame rod ceramic for
cracks, damage or tracking.
Check transformer and AC line for
proper input voltage to the control.
Check with full system load on the
transformer.