HSI90 - Systemdeckelmontage
unreinigungen schützen. Es dürfen nur unbeschädigte Teile montiert werden.
•
Die Lagerung der HSI90 Systemdeckel muss so erfolgen, dass sie zu keinen
niederen Temperaturen (<5 °C) und höheren Temperaturen (>30 °C) sowie
keiner direkten Sonneneinstrahlung ausgesetzt ist.
Entsorgung
Sofern keine Rücknahme- oder Entsorgungsvereinbarung getroffen wurde, zerleg-
te Bestandteile nach sachgerechter Demontage der Wiederverwertung zuführen:
• Elastomere nach den geltenden Umweltvorschriften entsorgen.
• Kunststoffe nach den geltenden Umweltvorschriften entsorgen.
• Verpackungsmaterial nach den geltenden Umweltvorschriften entsorgen.
Safety instructions and informations
Target group
The installation may only be carried out by technical experts.
Qualifi ed and trained individuals carrying out installation must have
• knowledge of general safety and accident prevention regulations as amended,
• knowledge of how to use safety equipment,
• knowledge of how to use hand tools and electric tools,
• knowledge of the relevant standards and guidelines for laying pipes/cables and
for backfi lling utility trenches, as amended,
• knowledge of the regulations and installation guidelines of the supply company
as amended,
• knowledge of the impermeable concrete directive and building waterproofi ng
standards as amended.
General information and intended use
According to their intended use, our products have been designed exclusively for
installation in buildings made from state-of-the-art construction materials. We do
not accept liability for use deviating from or beyond this unless our express written
confi rmation has been obtained in advance.
For warranty conditions, please see our current General Terms and Delivery
Conditions.
The system covers are for use in wall insert and aluminium fl ange HSI90. For
connecting smooth and corrugated cable ducts. The cold shrink sleeves support
a wide area of application. They are shrunk onto the cables by the system cover
socket without tools. Particularly gentle for thin-walled or temperature-sensitive
pipes.
The thermal sleeves also support a wide area of application. They are shrunk onto
the cables by means of the application of heat from the system cover socket.
Empty system cover sockets can be sealed with blind plugs.
Safety
This section provides an overview of all the main safety aspects for optimum
protection of personnel and a safe installation process.
If there is a failure to observe the instructions and safety information set out here,
this may result in signifi cant hazards.
HSI 90 system cover installation must comply with the relevant professional
association regulations, VDE provisions, national safety and accident prevention
regulations as well as company regulations (work and procedural instructions).
The fi tter must wear the relevant protective clothing.
Only intact components may be installed.
The following instructions are to be observed prior to installa-
tion of the HSI90 system cover:
tion of the HSI90 system cover:
WARNING!
Risk of injury in the event of improper installation!
Improper installation can result in signifi cant bodily harm and property damage.
• The nationally applicable laying and fi lling regulations for pipes and cables
are to be observed at all times.
• Seal the underground and cable substructure well prior to laying pipes/cables
so that the latter cannot subside.
NOTE!
No sealing due to incorrect assembly!
Improper installation can result in damage.
• The incorrect laying of cable and ducts, and improper fi lling of the cable
trench causes settlement, which can lead to damage and leaks.
• Cable entries not be opened until immediately before installing the cables to
avoid accidental damage during shell construction.
• Do not use a hammer or sharp object to open the sealing lid!
• The ducting may not be subjected to any mechanical stress via the cables
and/or pipes.
• No cleaning agents containing solvent may be used to clean the system
cover. We recommend using cable cleaner KR M.T.X.
• For details of other accessories and further information, see www.hauff-
technik.de and the technical specifi cation sheets.
• Cable entries that are not required can be used as pressure-tight reserve
entries if the Hauff seal of quality is free of damage.
• Opened cable feedthroughs, which are to be used as reserve feedthroughs,
should be fi tted with the new cover lid HSI90 D. Disassembled and/or
damaged cover lids must no longer be used!
• The cables and/or piping must be fi xed permanently in place after laying. As
a general rule, they should be run centrally via lid connecting elements and
may not be supported by them after shrinking.
• When shrinking with a fl ame, heat continuously all around to prevent local
overheating.
• For temperatures under 5° C it is recommended to get the cold shrinking
sleeve to room temperature. This will accelerate the shrinking process.
• If the cable insulation has been damaged, a hot-melt tape, such as "Hauff-
Hatetherm", can be applied to the cable prior to shrink-fi tting the sleeve.
• In principle the cold-shrink (KS) method is used on the outside of the
building.
EN
Personnel requirements
Qualifi cations
Risk of injury in case of inadequate qualifi cation!
Improper handling can result in signifi cant bodily harm and damage to property.
• Installation may only be carried out by qualifi ed and trained individuals who
have read and understood these instructions.
Skilled experts
Based on their specialist training, skills, experience and familiarity with the relevant
provisions, standards and regulations, skilled experts are able to carry out the
worked assigned, independently identifying and avoiding potential hazards.
Transport, packaging, scope of delivery and storage
Safety instructions in connection with transport
Safety instructions in connection with transport
NOTE!
Damage in the event of improper transport!
Signifi cant damage can occur in the event of improper transport.
• When unloading packaging items on delivery and in the course of in-house
transport, proceed with care and observe the symbols on the packaging.
Transport inspection
Inspect the delivery immediately on receipt for completeness and transport
damage. In the event of transport damage being visible from the outside, proceed
as follows:
• Do not accept the delivery or only do so subject to reservations.
• Make a note of the extent of damage in the transport documentation or
delivery note provided by the transporter.
Scope of delivery
The scope of delivery of the HSI90 D1x75 WS includes:
1 HSI90 D1x75 WS
1 Thermal sleeve
1 Centring strap
The scope of delivery of the HSI90 D1x75 KS includes:
1 HSI90 D1x75 KS
1 Cold shrink sleeve
1 Centring strap
The scope of delivery of the HSI90 D3x32 WS includes:
1 HSI90 D3x32 WS
3 Thermal sleeves
The scope of delivery of the HSI90 D3x32 KS includes:
1 HSI90 D3x32 KS
3 Cold shrink sleeves
The scope of delivery of the HSI90 D6x20 WS includes:
1 HSI90 D6x20 WS
6 Thermal sleeves
The scope of delivery of the HSI90 D6x20 KS includes:
1 HSI90 D6x20 KS
6 Cold shrink sleeves
Storage
NOTE!
Damage due to improper storage!
Signifi cant damage can occur in the event of improper storage.
•
Art. Nr.: 5090030000
Rev.: 00/2019-11-22
WARNING!
• Submit a claim for every defect as soon as it has been identifi ed.
• Make a note of the extent of damage in the transport documentation or
delivery note provided by the transporter.
Protect the HSI90 system cover from damage, damp and soiling prior to
installation. Only intact components may be installed.
5