Low Oil Pressure
This service code is indicated by Low Oil Pressure
scrolling across the digital display and two flashes on the
wireless monitor. The unit is equipped with an oil pressure
switch that uses normally closed contacts held open by
engine oil pressure during operation. Should oil pressure
drop below the 8 psi range, switch contacts close and the
engine will shut down.
To remedy the low oil pressure condition, add the
recommended oil to the FULL mark on the dipstick.
If the low oil pressure condition still exists, the engine will
start, then shut down again. The service code will appear.
In this case, contact an authorized dealer.
Under Voltage
This service code is indicated by Under Voltage scrolling
across the digital display and three flashes on the wireless
monitor. This condition is caused by a restriction in the
fuel flow, the electronic governing system not functioning
properly, a broken or disconnected signal lead, a failed
alternator winding, the control board circuit breaker is
open, or the generator is overloaded.
To remedy the problem, contact your installer or an
authorized dealer.
Over Voltage
This service code is indicated by Over Voltage scrolling
across the digital display and three flashes on the wireless
monitor. This feature protects devices connected to the
transfer switch by shutting the generator down if the
generator output voltage happens to increase above the
preset limit.
This condition is most likely caused by a failed voltage
regulator, alternator excitation circuit or a load imbalance.
To remedy the problem, contact your installer or an
authorized dealer.
Engine Does Not Start
This service code is indicated by Engine Does Not Start
scrolling across the digital display and four flashes on
the wireless monitor. This feature prevents the generator
from damaging itself if it continually attempts to start in
spite of another problem, such as no fuel supply. Each
time the system is directed to start, the unit will crank
for 10 seconds, pause for 10 seconds, and repeat. If
the system does not begin producing electricity after
approximately 2 minutes, the unit will stop cranking.
The most likely cause of this problem is no fuel supply or
incorrect fuel selector setting. See Fuel Selection Switch
in the installation manual. Check the internal and external
fuel shut off valves to ensure they are fully open. Other
causes could be failed spark plug(s), a loose electronic
governor connection, a failed engine ignition, or the engine
air filter is clogged. You may need to contact your installer
for assistance if you can't remedy these problems.
Low Frequency
This service code is indicated by Low Frequency scrolling
across the digital display and five flashes on the wireless
monitor. This feature protects devices connected to the
transfer switch by shutting the generator down if the engine
runs slower than 55 Hz for three seconds. This condition is
caused by a failed engine component, electronic governor
system, or by excessive loads on the generator. To resolve
the problem, contact your installer or an authorized dealer.
Engine Overspeed
This service code is indicated by Engine Overspeed
scrolling across the digital display and six flashes on
the wireless monitor. This condition can be caused by a
problem within the electronic governor system.
To resolve the problem, contact your installer or an
authorized dealer.
High Oil Temperature
This service code is indicated by High Oil Temperature
scrolling across the digital display and seven flashes on
the wireless monitor. The contacts of the temperature
switch are normally open. If the engine temperature
exceeds a predetermined temperature, the service code is
detected and the engine shuts down.
Common causes for this condition include running the
unit with an access doors removed, obstructed air inlet
or exhaust port, or debris in the engine compartment or
running unit with roof open.
To resolve the problem, let the engine cool down and
remove any accumulated debris and obstructions. Ensure
that the access doors are installed and the roof is closed
whenever the unit is running. If problem persists, contact
your installer or an authorized dealer.
Transfer Switch Service code
This service code is indicated by Transfer Switch Service
code scrolling across the digital display (if transfer switch is
equipped with service code detection) and eight flashes on
the wireless monitor.
The most likely cause of this service code is a blown fuse
in the transfer switch. To remedy the problem, contact your
installer or an authorized dealer.
No Wireless Communication
This service code is indicated by No Monitor
Communication scrolling across the digital display. The
SERVICE NEEDED red LED on the wireless monitor will
flash 20 fast pulses, pause 5 seconds, and repeat if there
is a loss in communication between the wireless monitor
and the generator.
To resolve the problem, move the wireless monitor closer
to generator. Re-link if necessary.
Battery Charge Circuit
This service code is indicated by Battery Charge Circuit
scrolling across the digital display. The most likely cause is
an electrical problem with the control panel. To remedy the
problem, contact your installer or an authorized dealer.