Standard Operation:

Wireless Monitor Status LED's
• The wireless monitor receives data from the
generator every 10 minutes and displays the
generator status through 3 LED's.
• Pressing the SYSTEM UPDATE button will provide
current generator status by flashing the status
LED's. When pressed, all 3 LEDs will flash until the
generator status is received.
NOTICE Generator control panel must be in AUTO mode
or no communication with monitor will occur.
• In order to conserve power and to extend battery
life, the LED's are not lit continuously; instead they
are briefly flashed as indicated below.
NOTICE During the weekly exercise cycle, the generator
Monitor/Generator
will run for 20 minutes, but it will not supply power to the
Status Codes
home. During the exercise cycle, the monitor will continue
blinking the GENERATOR READY green LED.
• GENERATOR READY - When active, the green LED
will flash once every 7 seconds. The green LED
indicates that the generator is in AUTO mode and
that it is ready to run in the event of a loss of utility
power.
• GENERATOR POWER - When active, the green
COLOR / ICON
LED will flash every 7 seconds. The green LED
indicates that the generator is supplying power.
green
GENERATOR READY
• SERVICE NEEDED - When active, the red LED will
green
GENERATOR POWER
flash in a sequence that corresponds to the service
code. For example, when Low Frequency scrolls
red
SERVICE NEEDED
across the control board, the red LED will flash 5
times with a 3 second pause between series of
blinks until it is reset or the condition is corrected.
BUTTON
SYSTEM UPDATE
Contact the nearest authorized service dealer if the
problem can not be fixed.
Generator Status
The wireless monitor receives data from the generator
NOTICE Service conditions will only be displayed on the
every 10 minutes and displays the generator status
basic monitor when the control board is placed in AUTO
through 3 status icons
mode.
Pressing the SYSTEM UPDATE button will provide
current Generator Status by flashing the status icons.
When pressed, all 3 icons will flash until the generator
status is received.
GENERATOR READY - When active, the shield
icon will flash green once every 7 seconds. The
green shield icon indicates that the generator is
in AUTO mode and that it is ready to run in the
event of a loss of utility power.
GENERATOR POWER - When active, the power
icon will flash green every 7 seconds. The green
power icon indicates that the generator is
supplying power.
SERVICE NEEDED - When the wrench icon
Other:
LED Lighting Codes
No status LEDs illuminated - Generator in OFF
mode or check and replace batteries.
Wireless communication lost issues can typically be
resolved by moving the wireless monitor closer,
within the home, to the standby generator. See
Optional Router Accessory Kit
Batteries Inserted - the shield LED will light for 5
seconds.
Linking Error or Not Linked - Each LED will light
then turn off in one direction, then the other
direction until a successful link is completed.
During the weekly exercise cycle, the generator
will run for 20 minutes, but it will not supply power to
• Linking Error or Not Linked - Each icon will light
the home. During the exercise cycle, the monitor
then turn off in one direction, then the other direction
will continue blinking the green shield LED.
until a successful link is completed.
Service Code Descriptions - name and number of
• During the weekly exercise cycle, the generator
flashes are listed on the back side of the wireless
will run for 20 minutes, but it will not supply power to
monitor.
the home. During the exercise cycle, the monitor will
continue blinking the green shield icon.
None of the service needed codes are cleared at
the wireless monitor. All alerts must be cleared at
Service Code Descriptions - name and number of
the generator control panel.
flashes are listed on the back side of the wireless
monitor.
XXXXX
XXXXX
None of the service needed codes are cleared at the
wireless monitor. All alerts must be cleared at the
generator control panel.
Optional Router Accessory Kit
The monitor has a line of sight range of up to 200 feet,
but this distance will decrease if the signal has to pass
through walls or other objects.