Electrical Connections; Layout Diagram And Connections - Aprimatic RSK24 SMT Notice D'installation

Masquer les pouces Voir aussi pour RSK24 SMT:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2.4

LAYOUT DIAGRAM AND CONNECTIONS

Fig. 3
J4
F2
F3
F1
M1
24 V AC
L
N
PH
N
TRANSFORMER
CAUTION! When the NC contacts (terminals 8,9,11) are not used, they must be jumpered to
the earth terminal (terminal 10 or 12). If you do not do this the automation WILL NOT work!
J1 terminal lock (13 pins):
1-2 Electric lock - 12 V AC output with maximum connectable load of 15W controlling the electric lock for approx. 1.5 seconds
in the opening stage.
3-4 LED Flashing light, 24 V DC- two-wire cables with min. section 1 mm
5-4 Warning light - 24 V DC output with maximum load of 3W for gate warning light.
6-10 Pedestrian start (NO).
7-10 24 V power supply for accessories.
8-10 Opening safety (NC safety contact).
9-10 Closing photocells input (NC safety contact).
11-12 STOP (NC safety contact) to stop wings.
13-12 START (NO) to start wing opening or closing.
J3 power terminal block with inputs for two 24 V DC motors - two-wire cable with min. section 1.5 mm
J4 connector for 230 V AC connection.
M1 230 V AC phase-earth-neutral connection.
FS1-2 24 V AC connection.
CN1 3-pin Aprimatic connector for accessories ( UNICO receiver, access control decoder, etc.).
CN2 10-pin connector for PL-ECO receiver.
FS3-4 BATT 24 V DC battery connection.
F1 fuse for primary transformer protection.
F2 fuse for external accessory protection (24 V DC).
F3 fuse for electronic circuit protection.
DS1 DISPLAY (7 segments and one dot) to display parameters and relevant values.
S1 RED button = Confi rm (used also before self-teach to actuate motor 1 in the Person Present mode).
S2 YELLOW button = Exit (used also to display connections on display).
S3 BLUE button = Scroll the values available (used also before self-teach to actuate motor 2 in the Person Present mode).
DL1 LED indicating that the board is powered up.
DL1
J3
-
+
M1
BATT
M1
MOTOR
1
M1 = motor 1st wing or single wing opening
M2 = motor 2nd wing opening
= NO type contact
= NC type contact
- 17 -
JP1
J2
J1
1
2
3
4
5
6
M2
-
+
-
+
+
-
M2
MOTOR
2
12 VAC 15 W max.
. DO NOT use other types of fl ashing light.
2

Electrical connections

CN1
DS1
Display
S2
S3
S1
YELLOW
BLUE
RED
(ESC)
(scorri)
(OK)
CN2
7
8
9
10 11 12
13
+
-
-
2
.

Publicité

Table des Matières
loading