also important that the correct level of acidity or alkalinity of the
pool water be maintained. This is measured in pH, a pH reading of
7.0 is considered neutral. Readings above pH 7.0 are alkaline and
readings below are acid. A desirable range is 7.2 to 7.4.
PUMP MAINTENANCE
1. Motors are self-lubricating.
2. Visually inspect motor for blockage of air vents on motor shell.
Remove any debris after shutting off breaker.
3. Shaft seals may become worn and must be replaced if leakage
is observed.
TROUBLESHOOTING
Problem
Motor Does Not
Disconnect switch or circuit breaker to OFF position.
Start
Fuses blown or thermal overload open.
Locked motor shaft.
Motor windings burned out.
Defective starting switch inside single-phase motor.
Disconnected or defective wiring.
Low voltage.
Motor Overheats
Low voltage.
(Protector Trips)
Motor windings connected for wrong voltage on dual voltage
motor.
Inadequate ventilation.
Motor Does Not
Low voltage.
Reach Full Speed
2-speed model set on low speed.
Motor windings connected for wrong voltage on dual voltage
motor.
High Pump
Discharge valve or inlet fitting closed too much.
Pressure
Return lines too small.
Low Pump
Pump running at reduced speed.
Pressure
Wrong rotation, 3-phase only.
Discharge valve or inlet fittings open too wide.
NOTE: If the recommendations in the Troubleshooting portion of this Owner's Manual do not solve your particular problem(s),
please contact your local dealer for service.
PARTS FOR MODELS A & RSPA SERIES
4
5
6
Motor Replacement List
Pump Models
Motor Type
S2A
S3A
S35A
Standard
S4A
S45A
S2AT
S3AT
S35AT
Two Speed
S4AT
S45AT
Possible Problem
7
1
2
3
Motor Kit Number
305562003
305562009
305562010
305562011
305562012
305562008
305562013
305562014
305562015
305562016
SERVICE AND REPAIR PARTS
Refer all service to your local dealer as his knowledge of your
equipment makes him the best qualified source of information.
Order all repair parts through your dealer. Give the following
information:
1. Unit Nameplate data
2. Description of part
Problem
Low Pump
Valve in suction or discharge line partly closed.
Capacity
Suction or discharge line partly plugged.
Suction or discharge line too small.
Pump running at reduced speed.
Impeller clogged.
Wrong rotation, 3-phase only.
Leakage of Water
Shaft seal requires replacement.
at Shaft
Pump Delivers No
Pump is not primed.
Water
Closed valve in suction or discharge line.
Leakage of air into suction system.
Impeller clogged.
Noisy Pump and
Worn motor bearings.
Motor
Valve in suction line partly closed.
Suction line partly plugged.
Vacuum hose plugged or too small.
Pump not supported properly.
Air Bubbles at Inlet
Leakage of air into suction line at connection or valve stem.
Fittings
Restriction in suction line.
Low water level.
Repair Part Kits and Overhaul Kits
Figure No.
1
02168409R000
2
305463176
05150015R000
8
05150015K
05200025R000
05200025K
05200020R000
3
05200020K
05300030R000
05300030K
05036504R000
05036504K
4
47025853R000
03087203R000
03087203K
5
03088903R000
03088903K
6
3116090602PK
7
14437902R000
8
n/a
Possible Problem
Part No.
Description
A-SERIES BRACKET
KIT, .625 MECH SHAFT SEAL
S2A S2AT IMPELLER
S2A S2AT IMPELLER KIT
(INCLUDES #2 & #4)
S3A S3AT IMPELLER
S3A S3AT IMPELLER KIT
(INCLUDES #2 & #4)
S35A S35AT IMPELLER
S35A S35AT IMPELLER KIT
(INCLUDES #2 & #4)
S4A S4AT IMPELLER
S4A S4AT IMPELLER KIT
(INCLUDES #2 & #4)
S45A S45AT IMPELLER
S45A S45AT IMPELLER KIT
(INCLUDES #2 & #4)
SQ. RING KIT (10 PER KIT)
SA CASE
SA CASE
(INCLUDES # 1, #4, #6, & #7)
S45A CASE
S45A CASE
(INCLUDES # 1, #4, #6, & #7)
1/4 PLUG WITH O-RING
SCREWS 10-12 x 1" PHIL PAN HD SS
SEE MOTOR REPLACEMENT LIST