Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SECTION E:
OPERATION
1. Open the Valve(s)
Open the valve(s) of the external fuel tank.
2. Start the Fuel flow
If using heater for the first time, press the red reset button in order to send fuel
to the fuel sump and release.
NOTE: Make sure there is no fuel leakage from the fuel line or joints.
Also make sure fuel tank is not too high. See installation instructions.
3. Connect the Heater
Connect heater into a proper electrical outlet. (refer to SECTION A). On digital
indicator pre-set "Two Dashes" will be showing.
NOTE: Do not connect to an outlet shared with other appliances.
4. Set Clock
IMPORTANT: Clock on the heater must always be set to current time and day.
NOTE: In the event of a power failure (more than approx. 30 min.), all clock and
day may be cancelled.
5. Setting of the Time and a Day of the Week.
1) Setting of the current time
1. Press the "▲MIN." button to set minutes and press the "▼HOUR" button to
set hours while in not operation.
2. Press the "SET" button to complete the set of the current time.
2) Setting of a day of the week
1. "dAy" sign is shown on the display and all of a day of the week will flash.
Press the "▲MIN." button or the "▼HOUR" button to set a day of the week.
NOTE: When pressing the "▲MIN." button at the position of "SAT", you can hear the beep sound and "SAT"
is not changed any more.
When pressing the "▼HOUR" button at the position of "SUN", you can hear the beep sound and "SUN" is
not changed any more.
2. Press the "SET" button to complete the set of a day of the week.
The current time and the day of week will show on the display.
MANUAL OPERATION
Operation of the heater is under the direct control of the user. Heat output will, however, be automatically adjusted
in accordance with the room temperature registered by the temperature sensor.
GB
5
BEFORE IGNITION
OPERATION
ENGLISH
Red Reset Button

Publicité

Table des Matières
loading

Table des Matières