IMPORTANT: This feature is for testing purpose only!
This heater also can be kept burning at desired combustion mode (High, Medium or low) manually, regardless of
room temperature.
1. Press the "▲MIN." button and "▼HOUR" button at the same time for more than three (3) seconds when ON /
OFF switch is "ON".
2. P1, P2 or P3 will be displayed on the Digital indicator;
P1 = Low mode
P2 = Medium mode
P3 = High mode
Then select desired combustion mode by pressing "▲MIN." or "▼HOUR" button. "▲MIN." button changes
combustion mode to higher, "▼HOUR" button changes combustion mode to lower.
3. To clear, press the "▲MIN." button and "▼HOUR" button at the same time for more than (3) seconds until
normal temperature display returns.
When the heater has been burning continuously for two hours at its highest setting, the burner will automatically
start an auto clean procedure. The display will show the auto cleaning code cl:05 running back to cl:01. The
procedure takes 5 minutes to clean the burner automatically while the heater will burn at its lowest setting. When
the burner is clean again, the heater will automatically switch back to the highest setting again.
If at any time a power failure occurs during operation, heater will turn off. When the power returns, the unit will
automatically restart with the following conditions. Please reset each setting when the settings are erased as
indicated below.
WHEN HEATER IS IN OPERATION
TIME LENGTH OF
POWER FAILURE
OPERATION
POWER SAVER
OPERATION
AUTO
OPERATION
CHILD LOCK
OPERATION
If at any time a power failure occurs when heater is not in operation, the unit will basically start the operation while
keeping the same condition before the power failure. However, when the power failure continued more than 3
seconds, the following settings will be erased. Please reset each setting.
WHEN HEATER IS NOT IN OPERATION
IN BACKUP MEMORY
OUT OF BACKUP MEMORY Clock and Day setting
GB
9
MANUAL COMBUSTION
AUTOMATIC CLEANING MODE
POWER FAILURE RECOVERY SYSTEM
0LESS THAN 3
SECONDS
Restart the combustion
Start the combustion from the
with the same condition
beginning.
before the power failure.
Keep the same condition
Keep the same condition before
before the power failure.
the power failure.
Keep the same condition
Keep the same condition before
before the power failure.
the power failure.
Keep the same condition
The setting will be erased.
before the power failure.
(refer to SECTION E)
Child lock operation
Child lock operation
MORE THAN 3 SECONDS
IN BACKUP MEMORY
ENGLISH
OUT OF BACKUP MEMORY
Start the combustion from the
beginning.
Set temperature will change to
13˚C (56˚F) for safety.
Set temperature and room
temperature will blank that at
least more than 30 min. power
failure has occurred.
To stop the blinking the
set temperature and room
temperature, press any button
once.
Keep the same condition before
the power failure.
The setting will be erased.
(refer to SECTION E)
The setting will be erased.