SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W × H × D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
(1)
Heat and vaporized water are produced by fuel combustion. Heat rating does not account for heat loss due to
condensation of water vapor.
(2)
External tank to be purchased separately. (Consult your supplier for options.)
(3)
It is excluded from CE marking.
Your heater is equipped with a number of integral safety features.
Please familiarize yourself with these features. If the heater shuts
down due to the operation of any safety device, ensure the problem
is identified and corrected. Note that normal combustion flames
inside the combustion chamber, can be seen through some "peep
holes", located in the front bottom left hand corner of the hot air
outlet louvers.
1. Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to prevent
fuel overflow. Error code will be displayed on the digital indicator.
2. Fuel Strainer
Special strainer catches any dirt or impurities present in the fuel before it is sent to the burner.
3. Overheat Protector
Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor malfunc-
tion or abnormal combustion.
4. Power Failure Recovery System
If power fails during heater operation, heater will turn off. When power resumes, heater will automatically reignite
to maintain the selected room temperature.
NOTE: The operation varies depending on the time length of power failure and other conditions.
GB
Please see Section E "Operation" for more details.
5. Fully Vented System
1
Flue Pipe system provides outside air for combustion and vents all combustion products to outdoors.
FF-95
92.4% (1)
High - 9.50 kW (32,400 BTU/h)
Med - 5.49 kW (18,700 BTU/h)
Low - 2.96 kW (10,100 BTU/h)
High - 1.07 L/h
Med - 0.620 L/h
Low - 0.334 L/h
External tank (2)
Paraffin only
760 × 700 × 427 mm
34 kg
70 ~ 80 mm diameter
3 m, 3 bends or less (Section I "Installation")
230 Volts AC, 50 Hz
(220 Volts AC, 50/60 Hz) (3)
Preheat - MAX 280 W
Burning - MAX 52 W
SAFETY FEATURES
Circulation fan
Heat shield plate
Heat chamber
Peep hole
Flame sensor
Burner ring
Igniter
Burner
Adjustable leg
Blower motor
ENGLISH
Overheat protector
Heat exchanger
Fuel pipe
Fuel pump
Red Reset button
Fuel sump
Integral fuel
strainer (inside)
Drip tray