Télécharger Imprimer la page

Barrier Installation; Electrical Connection - Aprimatic AT163 Instructions Pour L'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Barrier installation

4.1 BARRIER INSTALLATION
The two barriers only differ for some mechanical parts contained inside the box (fig. 7).
Such differences do not modify the installation sequence or the adjustment of the barriers.
Fig.7
1 Control unit
2 Hydraulic control unit
3 Hydraulic piston for lever motion
4 Compensation spring
5 Beam control lever
6 Hydraulic piston supply hoses
7 Oil fi ller
8 Mechanical stop pad

4.2 ELECTRICAL CONNECTION

Caution
The electrical connection of the operator to the
electronic control unit must be done only by skilled
personnel according to the instructions provided
with the control unit.
The electronic control unit can be fi xed inside the box
using the special holes.
For the connection of electrical control and safety
appliances, follow the wiring diagram.
If, during opening or closure, the electric motor of the
hydraulic control unit runs, but the barrier does not
move, proceed as follows:
– cut the power off;
– check the electrical connection of the entire circuit;
– reverse the poles of the electric motor if necessary.
Motorway barrier 163/164
15
14
7
10
9
13
4
6
2
1
9 Stroke end control cam
10 Limit switch
11 Supporting frame
12 Cooling fan and baffl e plate
13 Compensation spring chain
14 Oil cooling fan thermostat wire
15 Motor power cable
Fig.12
3x1
2x1,50(230V) 3x1,5(24V)
2
3
4Fx1,5
1
8
Legend:
1 - Hydraulic control unit motor power supply
2 - 24V-230V fl ashlight
3 - Receiving radio control
4 - Key-contact
5 - Emitting photocell
6 - Receiving photocell
7 - Internal control panel
8 - Electronic control unit
- 12 -
8
5
8
3
7
12
11
5
4
2x1
2x1
7
6A
Ie=30 mA
230 V
50 Hz
2x1,50
R
6
4x1

Publicité

loading

Ce manuel est également adapté pour:

At164