POWER SUPPLY VOLTAGE CHANGE

IMPORTANT: This manual section concerns qualified personnel only.
The following instructions are to be ignored by the user.
Make sure the device is not connected to the mains (unplug the power cord).
230 V
If the mains voltage is
, set the connector to the 230Vac position (see the picture 3), according
to the PCB indication (looking at the connector front, the central pin is connected to the right one).
115 V
If the mains voltage is
, set the connector to the 115 Vac position (see the picture 4), according
to the PCB indication (looking at the connector front, the central pin is connected to the left one).
Refit the power supply circuit metallic screen and the device lid.
Before connecting the device to the mains, make sure that the fuse (inside the IEC power supply
connector of the rear panel) is the correct current rating for the mains voltages (read the fuse
indication below the connector).
64
Remove the lid.
The power supply circuit is under the ventilation
(see picture 1), which can be removed by unscrewing the 2
screws.
The
voltage
change
connector
highlighted by a square in the picture 2.