RCF Invision 354MP Manuel De L'utilisateur page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

F
CHIME LEVEL (a trimmer adjustable by using a small screwdriver).
G
SEQUENTIAL COMMAND with removable connector (activated when the 2 pins are short-
circuited) to send continuously (with max. volume) either the chime (selected through the dip-
D
switch 7 PRESET
) or an alarm tone (selected through the dip-switch 8 PRESET
H
Internal relay contacts (3 pole removable connector)
The internal relays switches when a priority command is present.
1 – normally open
2 – common
Max. voltage: 24 V; max. current: 0.5 A.
J
REMOTE CONTROL terminal
SEL:
music source selection (when linked to ground)
GND:
common ground
BGM:
music volume
MASTER:
master volume
REMOTE VOLUME CONTROL
The MASTER and BGM remote volume controls are independent. Insert a potentiometer between
the respective contact and the ground.
The potentiometer nominal value affects the operating
range (referring to the front panel settings): the
higher the value, the wider the adjustable range.
Its value can be typically from 10 kΩ to 100 kΩ, the
optimal action is obtained with an inverse logarithmic
curve potentiometer, but it is also acceptable a linear
response one.
The music remote control is relative to the activated music source (either internal or external).
The maximum range that can be obtained is 40 dB (relative to the signal adjusted by the main
settings).
IMPORTANT: If a remote control potentiometer is not foreseen, it is necessary to short-circuit the
respective contact to ground (through a wire), otherwise the MASTER volume and / or the BGM
volume are set to zero (muted).
MUSIC SOURCE REMOTE SELECTION
It is obtained by connecting a push-button between the SEL e GND contacts.
The selection is cyclic: CD/USB – MP3 player and tuner, AUX INPUT
3 – normally closed
MASTER
GND
o
D
).
BGM
10 kΩ ÷
100 kΩ
GND
, no music.
45
1
2
3
10 kΩ ÷
100 kΩ
SEL
GND

Publicité

Table des Matières
loading