6
Mechanical Settings of the Microwave Field
6.1.1
Tilting the microwave module
45°
7
Remedying Malfunctions
Symptom
Door reverses
Door reverses
Door opens inadvertently
Door does not open –
sporadic non-detection
of an individual
Late detection or
non-detection of persons
8

Technical Data

Technology
Transmitting frequency
Transmitting power
Operating voltage
Operating current
Mains frequency
Temperature range
Air humidity
Mounting height
Relay output
Switching voltage
Switching current
Switching capacity
Housing
Weight
Protection class
Min. detection
speed
Cable length
Approvals
Overview of countries
8
45°
Possible cause
– Sensor sees door
– Sensor sees swing door
– Interference source affects microwave field
(e.g. fluorescent tubes)
– Large group of persons
approaching
– Field too small
– Installation too high
Microwave motion detector with
planar module technology
24.125 GHz
< 20 dBm
12–36 V DC / 12–28 V AC
approx. 50 mA at 24 V DC, 24° C
50 Hz
–20° C to + 60° C
0 to 90 % rel., without condensation
up to 4 m
Potential-free changeover contact
max. 48 V ACDC
max. 0.5 A AC / 1 A DC
max. 60 VA / 30 W
Cover: PC; floor plate: ABS
Dimensions (W x H x D):
176 x 62 x 52 mm
150 g (without cable)
Suitable for use acc. to IP 54
5 cm/s (in sensor axis)
< 5 cm/s with SMD+ (inclination angle 35°)
3 m
CE 0682 !
EU; EFTA; US; CA
Montageanleitung GC 302 R
6.1.2
Swivelling the microwave module
–30°
+30°
Remedy
– Change the inclination angle of the radar module
– Install sensor higher and if possible directly above the door hinge
– Increase CTM level
– Swivel the sensor in the direction of the door opening
– Activate the interference suppression filter
– Activate the special filter function MTO
(Mass Traffic Optimisation)
– Decrease the CTM level (switch off)
– Check field size
D
– Activate high mounting height
FCC/IC
This device contains a 24 GHz transmitter with the FCC-ID UXS-IPQ05 and IC-ID
6902A-IPQ05. It meets the requirements of Part 15 of the FCC regulations and
the RSS-210 standard of Industry Canada.
Operation is subject to the following conditions: This device (1) must not cause
any dangerous malfunctions and (2) must cope with all malfunctions. This also
includes malfunctions that can cause undesired functions.
Warning: If any changes or modifications are made to this
device that are not expressly approved by GEZE GmbH,
the FCC approval to operate this device can expire.
–30°
Refer to chapter
6.1.1
5.2.3
6.1.1
+
+
5.2.3
F
6
1
+
5.2.3
B
4
5.2.3
5.2.3
+
+
F
4
1
123457 , 70705-9-9521 A-St.0
+30°