GEZE GC 302 R Instructions De Montage page 7

Radar détecteur de mouvement avec reconnaissance de direction pour commande d'ouverture des portes automatique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Recommendation: First, select the enhanced function that is closest to the requirements and then change the parameter levels correspondingly.
Enhanced functions
Parameter
Direction recognition
Field size
Relay hold interval
Output signal
SMD function
Mounting height
Cross traffic
Interference suppression
SMD field size
Field geometry
Configuration of individual parameters
Key
Parameter
code
Enhanced functions
C
Direction recognition
B
+
F
4
Mounting height
+
Field geometry
F
8
Field size
D
+
F
1
Relay hold interval
+
Output signal
F
2
+
F
3
SMD function
+
SMD field size
F
7
CTM
+
F
5
(cross traffic
masking)
Filter for
+
interference
F
6
suppression
123457 , 70705-9-9521 A-St.0
+
*
C
1
Key code
Standard
B
ON, forwards
6
D
+
1 s
F
1
+
Active
F
2
+
F
3
Off
+
Up to 3 m
F
4
+
Low
F
5
+
Off
F
6
+
1
F
7
+
Wide
F
8
Level Short description
1*– 6 Predefined settings for standard
applications (see table)
1
Off
2
Backwards
3*
Forwards
4
Forwards with MTO (see chap. 7)
1
High (3–4 m)
2*
Standard (up to 3 m)
1
Narrow field
2*
Wide field
1 – 3
Small
4 – 6*
Medium
7 – 9
Large
1
0.2 s
2
0.5 s
Short
3
0.8 s
4*
1.0 s
5
1.5 s
Medium
6
2.0 s
7
2.5 s
8
3.0 s
Long
9
4.0 s
1*
Active: The relay picks ups when
a detection takes place
2
Passive: The relay drops out when
a detection takes place
Off
1*
2
0.5 s
3
1.0 s
Decreasing sensitivity
4
1.5 s
5
2.0 s
6
0.5 s
7
1.0 s
Constant sensitivity
8
1.5 s
9
2.0 s
(plus SMD+)
1*– 3
Small
4 – 6
Medium
7 – 9
Large
1
Off
2*– 3
Low
4 – 6
Medium
7 – 9
High
1
On
Prevention of possible
spurious tripping by fluorescent
2*
Off
tubes.
Montageanleitung GC 302 R
+
+
C
2
C
3
Pavement
Retirement home
ON, forwards
OFF
7
6
0.8 s
2 s
Active
Active
Off
Decreasing, 2 s
Up to 3 m
Up to 3 m
Medium
Off
Off
Off
1
5
Narrow
Wide
5.2.4
Explanation of individual parameters
Field size
/ field geometry
D
Depending on the field geometry (wide/narrow field), the field size can be set
correspondingly.
Narrow
field:
Min. 0.7 x 0.6 m (WxD)
Max. 2.7 x 1.9 m (WxD)
Specified values measured with mounting height 2.2 m and inclination angle 35°.
SMD function
F
SMD = Slow motion detection: Very small (quasi-static) movements are detected
as soon as the sensor is activated. Only when no more movements are registered
during the set monitoring period does the sensor relay the corresponding signal
to the door controller. The sensitivity during this monitoring period can be set to
decreasing or constant.
SMD+: Triggers the sensor when very slow movements occur.
In this way, even objects < 5
not detected with the normal detection area are reliably
identified (retirement home setting). In order to prevent the
door from being kept open too long, the SMD+ field is half as
large as the detection area.
SMD field size
~
~
The SMD field sizes approximately correspond to those of the detection area,
+
+
i.e.
F
7
5
Cross traffic masking CTM
The CTM prevents a door from being inadvertently opened by peoply who only
walk past it but do not want to enter.
5.2.5
Status query with remote control
The status query is to find out what parameters have been set. For this to take
place, the connection to the sensor has to be established and the corresponding
key code has to be entered. Next, a numerical key lights up that indicates the
respective parameter level.
+
+
C
4
C
5
Entry hall
Supermarket
ON, forwards
ON, forwards
6
9
0.2 s
1.5 s
Active
Active
Off
Decreasing, 2 s
Up to 3 m
3–4 m
Low
Off
Off
Off
1
5
Narrow
Wide
+
F
8
Wide
field:
D
Min. 1.1 x 0.6 m (WxD)
W
Max.4.7 x 1.7 m (WxD)
+
3
and SMD+
cm
(35° inclination angle) that are
s
+
F
7
+
D
5
+
F
5
Optimum sensor settings:
– Narrow field
– Inclination angle 30°–45°
+
C
6
High mounting
>
3 m
(9.84')
ON, forwards
9
1 s
Active
Off
3–4 m
Medium
Off
1
Wide
D
W
* Factory setting
7

Publicité

Table des Matières
loading

Table des Matières