1) DESCRIPTION
Automation system for balanced sectional doors (1/20 limit switch ratio) and rolling doors (1/40 limit switch ratio) available in various
versions:
- with manual release (S versions) or manual chain operation (M versions).
- with single-phase or three-phase power supply (T series)
- with adjustable cam-activated limit switch with standard wiring or absolute Encoder (ESW versions) for quick connection to the THINKY
central control unit, using wiring available in different lengths.
- manned control (UP versions).
The following table shows the various models* and their main features:
LS
Model
ratio
VN.S20
1/20
VN.S40
1/40
VN.ST20
1/20
VN.S20UP
1/20
VN.S40UP
1/40
VN.S20ESW
1/20
VN.ST20ESW
1/20
VN.M20
1/20
VN.M40
1/40
VN.MT20
1/20
VN.MT40
1/40
VN.M20UP
1/20
VN.M40UP
1/40
VN.M20ESW
1/20
VN.MT20ESW
1/20
* Other models available on request are not listed in this table
Accessories
CABLE VN.ESW 5
Quick connection cable between VN.__ESW motorsand the THINKY central unit (5 metres)
CABLE VN.ESW 8
Quick connection cable between VN.__ESW motorsand the THINKY central unit (8 metres)
CABLE VN.ESW 11
Quick connection cable between VN.__ESW motorsand the THINKY central unit (11 metres)
2) TECHNICAL DATA
Figures 1 and 2 show the overall dimensions of the VN.S / VN.M models.
V N . S 2 0 U P - V N . S 2 0 E S W -
Power supply
Consumption
Torque
Maximum outbound ro-
tations
Exit rounds
Shaft Hole
L.S. reduction ratio
Working cycle
Protection degree
Operat. temperature
Door surface
Lubrication
Weight
3) INSTALLATION
Before proceeding to install the system, make sure that the door is balanced and slides well. Check that the ropes, the springs and the
parachuting system are in good conditions. For doors that have not been installed recently, check also all the other parts subject to wear
and tear. The above instructions are essential for the safety of the system and the reliability of the operator.
Emergency
Power
operation
voltage
Manual release
230Vac single phase
Manual release
230Vac single phase
Manual release
400Vac three phase
Manual release
230Vac single phase
Manual release
230Vac single phase
Manual release
230Vac single phase
Manual release
400Vac three phase
Chain operated
230Vac single phase
Chain operated
230Vac single phase
Chain operated
400Vac three phase
Chain operated
400Vac three phase
Chain operated
230Vac single phase
Chain operated
230Vac single phase
Chain operated
230Vac single phase
Chain operated
400Vac three phase
VN.S20 - VN.M20 - VN.M20UP
VN.M20ESW
230Vac (50-60Hz)
3,3 A
130 Nm
18
1/20
30%
35m
2
/max
14,7 kg
Adjustable
Absolute
limit
Encoder
switches
YES
--
YES
--
YES
--
YES
--
YES
--
--
YES
--
YES
YES
--
YES
--
YES
--
YES
--
YES
--
YES
--
--
YES
--
YES
Description
VN.S40 - VN.M40
VN.ST20 - VN.MT20
VN.S40UP - VN.M40UP
VN.ST20ESW - VN.MT20ESW
38
24 r.p.m.
1" (25,4mm)
1/40
IP40
-20°C /+50°C
Oil
14,7 kg
Quick wiring
Standard
THINKY
wiring
--
YES
--
YES
--
YES
--
YES
--
YES
YES
--
YES
--
--
YES
--
YES
--
YES
--
YES
--
YES
--
YES
YES
--
YES
--
VN.MT40
3PH 400Vac (50-60Hz)
1,7 A
180 Nm
18
1/20
50%
40m
2
/max
14,7 kg
14,7 kg
EN
Man ned
--
--
--
YES
YES
--
--
--
--
--
--
YES
YES
--
--
38
1/40
17