Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
• Before installing the automatic system read the instructions
hereunder carefully.
• It is strictly forbidden to use the product VN.S40V for applications
other than indicated in this instruction handbook.
• Show the user how to use the automation system.
• Give the user the part of the leaflet which contains the instructions
for users.
• All Benincá products are covered by an insurance policy for any
possible damages to objects and persons caused by construc-
tion faults, under condition that the entire system be marked CE
and only Benincá parts be used.
OPERATiNg LiMiTS AND WARNiNgS
This geared motor has been specially studied to activate double-
leaf folding doors and industrial sliding doors. Before installation,
check the sliding of the door. For doors that have not been installed
recently, check also all the other parts subject to wear and tear.
The above instructions are essential for the safety of the system
and the reliability of the operator.
iNSTALLATiON (fig. 4)
Thanks to its versatility, this geared motor can be assembled not
only on the right-side or left-side of the door, but also horizontally
(fig. 2) or vertically (fig. 3).
WiRiNg (fig. 5)
GND
Earth.
Not used.
SWO
Open limit switch 1x0.5 min.
SWC
Close limit switch 1x0.5 min.
COM AUX
Common of the contact at disposal
Not used.
AUX
3A, 24Vdc max.
L1/M
Phase
L2/COM
Com.
L3/M
Phase
Not used.
COM SW
Common of Limit switch 1x0.5 min.
---
Not used.
The 25µF capacitor must be connected to the motor terminals 7
and 8 of THINK control unit.
To use the micro-switch supplied as a safety limit switch in the
closing phase, modify the cable positions as per fig. 6.
ADjuSTMENT OF ThE LiMiT SWiTChES
The geared motor is equipped with 4 microswitches:
Red limit switch
Opening limit switch (SWO)
Blue limit switch
Opening over-travel (SWO XT)
Yellow limit switch
Closing limit switch (SWC)
Black limit switch
At disposal of the accessories (AUX)
To adjust the cams proceed as follows:
• Manually move the door until it is almost closed and adjust the
SWC cam until the micro-switch is almost triggered (Fig. 9).
• Tighten the dowel shown in Figure 10 by using a 2.5mm socket
head key.
• By using the same key, carry out the micrometric adjustment of
the cam, as shown in Figure 11.
• Repeat the operation while opening the door and adjust the SWO
cam.
12
WARNiNg
VN.S40V
• Then position the SWO XT cam so that it is activated slightly
delayed with respect to the SWO cam.
• Power the automatic unit and operate it (if it is a closing operation,
invert wires 1 and 3 of the motor power supply, fig. 6 and 7).
• Should further adjustments be required, turn the micrometric
adjustment dowel.
Figure 10 shows the wire diagram of limit switches in single-phase
motors.

Technical data

Power supply
Consumption
Power
Torque
Door max. width
Exit rounds
L.S. reduction ratio
Jogging
Thermal switch trig.
Operat. temperature
Capacitor
Lubrication
Weight
Dimensions: see fig.1
VN.S40V
230V
3A
550W
45Nm
9m
48rpm
1/40
40%
130°C
-20°C / +70°C
20µF
Agip Blasia 32
15kg

Publicité

Table des Matières
loading

Table des Matières