Fuel Cell and Metering Valve
Installing Metering Valve to Fuel Cell Prior to Use
To install the metering valve to a fuel cell:
1. Press downward on the front side of the valve (stem side) until it seats.
2. Press downward on the rear side of the valve until it seats.
3. The valve is now completely seated onto the fuel can and can be inserted into the tool.
. 1
NOTE:
Paslode Impulse™ fuel cells are marked with an expiration date on the bottom of the can.
For maximum performance use fuel before expiration date.
Paslode Impulse Fuel Cell Disposal Guidelines
Paslode, the industry leader in cordless technology provides this information to assist users with the
proper disposal of discarded fuel cells. Acceptable disposal options vary depending on the type of
fuel cell users. All users must consider federal, provincial and local solid waste regulations to ensure
that discarded fuel cells are disposed of properly. Users must contact their local solid waste authority
for further guidance.
Paslode takes no responsibility for proper fuel cell disposal. Proper disposal remains the responsibility
of sellers and users. All sellers and users must contact their local solid waste authority to determine if
any federal, state or local regulation prohibits or restricts disposal.
10
. 2
DANGER
Paslode Impulse Fuel Cells are flammable.
Do not smoke when installing the metering valve!