GB
C. SETUP
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION /
OR MAINTENANCE.
Accessing the control settings – (Fig. 4 and 5)
1.
Loosen the screw in the bottom of the grille and remove the front grille.
2.
Carefully pull the inner cap from the centre of the fan away from the chassis.
3.
Adjust the settings as outlined below.
Trickle speed selection (6l/s or 9l/s) – (Fig. 7)
In normal running mode the fan can extract at either 6l/s (22m
rate. The fan will boost to 15l/s (54m
• Factory set at 6l/s (22m
• Remove jumper connector (JP1) if 9l/s (32m
required.
Airflow detection system – enable/disable (Fig. 8)
The airflow detection system will detect the installation duct resistance and also react to
external wind conditions to ensure the fan maintains a constant extraction rate. This can
cause the fan to ramp up and down and in most applications will not be required. To turn
this feature on, complete the following:
• Push switch (SW1) into the on position to turn on constant flow mode.
• Push switch (SW1) into the off position to turn off constant flow mode.
(Factory set)
IMPORTANT – On first power up, the fan will run through its initialisation routine. This
will involve the fan running on maximum speed for 10-20 seconds. After which the fan
will run as normal and will not need to be initialised/calibrated again. The fan will
remember its settings if there is a power cut.
D. SERVICING AND MAINTENANCE.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE.
1. At intervals appropriate to the installation, the fan should be inspected and cleaned to
ensure there is no build up of dirt or other deposits.
2. Carefully push the front panel of the grille upwards away from the base part of the
grille (fig. 6).
3. Wipe the inlets and front face with a damp cloth until clean.
The fan has sealed for life bearings, which do not require lubrication.
3
/h) when the LS connection is switched.
3
/h).
4
3
/h) or 9l/s (32m
3
/h) extract flow rate is
3
/h) flow