Installation and Wiring Instructions for the Sylph Range of Extractor Fans.
IMPORTANT:
READ THESE INSTRUCTIONS
BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures higher than 40°C or less than –5°C.
• Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate
standards of your country and MUST be installed by a suitably qualified person.
B. The Fan should be provided with a local isolator switch capable of disconnecting all poles,
having a contact separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating
label.
D. The Fan should only be used in conjunction with the appropriate Vent-Axia products.
E. The fan should only be used in conjunction with fixed wiring.
F. When the Fan is used to remove air from a room containing a fuel-burning appliance,
ensure that the air replacement is adequate for both the fan and the fuel-burning appliance.
G. The Fan should not be used where it is liable to be subject to direct water spray for
prolonged periods of time.
H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be
fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan.
I. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
J. Young children should be supervised to ensure that they do not play with the appliance.
DESCRIPTION
The Sylph 100mm fan is a continuously running extract fan for kitchens, utility rooms,
bathrooms and toilets.
The product incorporates an airflow detection system that detects the installation duct
resistance and maintains the correct fan speed to achieve the preset extract flow rate of
either 6l/s, 9l/s or 15l/s, minimising energy use and noise (see Section C-Setup for more
information).
Long life ball bearing DC motor with anti-vibration mounts provides virtually zero noise
transmission into plasterboard/panels for silent operation.
The fan can be wall or panel/ceiling mounted.
ACCESSORIES (not supplied)
WALL FITTING KIT
A 100mm wall kit is available for installing into most walls using the liners supplied.
(Stock ref. 8000000002)
2