6.2.2
Positioners with stainless steel enclosure 6DR5..2, flameproof stainless steel
enclosure 6DR5..6, and narrow aluminum enclosure 6DR5..1
Removal, cleaning and installation of the screens
1. Disconnect the pneumatic auxiliary power supply.
2. Remove the pipelines.
3. Remove the metal screen from the bores carefully.
4. Clean the metal screens, e.g. using compressed air.
5. Insert the screens.
6. Connect the pipelines again.
7. Feed the pneumatic auxiliary power supply.
6.3
Repair/Upgrading
Send defective devices to the repairs department, together with information on the malfunction and the cause of the
malfunction. When ordering replacement devices, please provide the serial number of the original device. You can find the
serial number on the nameplate.
6.4
Return procedure
Enclose the bill of lading, return document and decontamination certificate in a clear plastic pouch and attach it firmly to the
outside of the packaging. Any devices/replacement parts which are returned without a decontamination declaration will be
cleaned at your expense before further processing. For further details refer to the operating instructions.
See also
Return document (http://www.siemens.com/processinstrumentation/returngoodsnote)
Decontamination declaration (http://www.siemens.com/sc/declarationofdecontamination)
6.5
Disposal
42
Devices identified by this symbol may not be disposed of in the municipal waste
disposal services under observance of the Directive 2002/96/EC on waste electronic
and electrical equipment (WEEE).
They can be returned to the supplier within the EC or to a locally approved disposal
service. Observe the specific regulations valid in your country.
SIPART PS2 (6DR5...)
A5E03436620-07, 10/2015