Technical Data; Installation - Siemens simovert masterdrives CBP/CBP2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

05.2006
4.2

Technical Data

Order number
Size (length x width)
Degree of pollution
Mechanical strength
During stationary duty
- Deflection
- Acceleration
During transport
- Deflection
- Acceleration
Climate class
Type of cooling
Permissible ambient or coolant
temperature
- During operation
- During storage
- During transport
Permissible humidity rating
Power supply
Transfer rate
Duration delay
Cable length (max.)
between two nodes
4.3

Installation

NOTE
Siemens AG
6SE7087-6NX84-0FF5
SIMOVERT MASTERDRIVES
6SE7090-0XX84-0FJ0
90 mm x 83 mm
Pollution degree 2 according to IEC 644-1(DIN VDE 0110/T1, moisture
condensation is not permissible in operation
According to DIN IEC 68-2-6 (for correctly installed board)
0.15 mm in frequency range 10 Hz to 58 Hz
19.6 m/s² in frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
Class 3K3 according to DIN IEC 721-3-3 (in operation)
Natural-air cooling
0° C to +70° C (32° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
Relative air humidity
DC 5 V, max. 600 mA, internally from the basic unit
DC 24 V, max. 200 mA, external voltage supply
11 MBaud
max. 3 clock times
- 40 m (plastic)
- 300 m (glass fiber)
Table 4-1
Technical Data
If the inverters/converters are ordered with optional functions, the
optional boards are already installed in the units when they are
delivered.
It is possible to retrofit optional boards and this can be carried out by
the user.
For this purpose, there are either three or up to six slots on the basic
unit depending on the type of construction for mounting the optional
boards.
An exact description of installation is included with the relevant basic
unit. As the unit has to be removed and opened in order to install
optional boards, attention must be paid to the ESD measures. Please
refer to the operating instructions of the basic unit in this regard.
Generally, you can install the SLB (SIMOLINK) optional board in any
slot, but you must take into account that a sensor board always
requires slot C.
Option boards
SLB – SIMOLINK Board
≤ 95 % during transport and storage
≤ 85 % in operation (moisture
condensation not permissible)
4-3