EB2 – Expansion Board 2
Loadability of the
relay contacts
Jumper settings
6.5

Start-up

NOTE
6-6
Type of contact
Maximum switching voltage
Maximum switching capacity
Required minimum load
The analog input can be used as a voltage input or as a current input.
The analog output can be used as a voltage output or as a current
output.
Switchover is made via jumpers on the lower section of the board. The
assignment is shown in the following table:
Connector
Significance
X498
Current/voltage input switchover at AI1
Jumper 1 + 2
Jumper 2 + 3
X499
Current/voltage output switchover at AO
Jumper 1 + 2
Jumper 2 + 3
Table 6-5
Jumper settings
After installation of the EB2 terminal expansion board has been
completed, an automatic self-test is carried out when the basic unit
(converter/inverter) is powered up.
If you want to use an input or output of the option board, you have to
activate the respective function block.
Please bear in mind that if two EB2 terminal expansions are installed,
each board is provided with its own parameter set.
Please refer to the Compendium for further information regarding
parameterization of the EB2 terminal expansion board.
Changeover contact
60 V AC, 60 V DC
16 VA at 60 V AC (cos ϕ = 0.4)
60 VA at 60 V AC (cos ϕ = 1.0)
24 W at 60 V DC
1 mA, 1 V
Current input
Voltage input
Current output
Voltage output
6SE7087-6NX84-0FF5
Option boards
05.2006
Siemens AG
SIMOVERT MASTERDRIVES

Publicité