Instructions for installation and use
● Installation may only be performed by a qualified electrician or
similarly qualified person.
● A three-phase shut-off device with a 3 mm contact opening must
be provided during installation. This is provided by the fuse.
● Always use silicone cables that are heat-resistant up to 150 °C
to connect the heater.
● Only install one sauna heater in the cabin. The Concept R combi
sauna heater must not be used together with other sauna heat-
ers in a sauna cabin.
● The roof and walls of the sauna cabin are manufactured from
low-resin, untreated or thermally treated woods, e.g. Nordic
spruce, hemlock, pine or fir, or from laminated wooden materi-
als. If laminated wooden materials are used, make sure that the
adhesive does not produce formaldehyde. If other materials apart
from wood are used in the sauna cabin, these materials must
be heat and corrosion-resistant and must not have any negative
effects on the health of the sauna users.
● The height of the sauna cabin must be at least 2.0 m.
● Observe the specifications on volumes and on ventilation of the
sauna cabin in chapter 10. Technical data on page 26.
● When positioning the sauna heater, observe the minimum safety
distances (see chapter 4.2. Safety distances on page
● Also comply with the regulations applicable in the installation
location.
WORLD OF WELLNESS
p. 7/26
EN
).
12