general information
EN
1.2

listing approvals

This appliance has been tested in accordance with the CSA Standards for fixed and location-dedicated electric
room appliances in the United States and Canada. If you need assistance during installation, please contact your
local dealer.
note:
This appliance must be electrically wired and
grounded in accordance with local codes or,
in the absence of local codes, with National
Electric Code ANSI/NFPA 70-latest edition
in the United States or the Canadian Electric
Code, CSA C22.1 in Canada.
1.3

general instructions

Prior to plugging your appliance into an electrical outlet, verify that the house circuit breakers for the outlet
are on.
The appliance may emit a slight, harmless odour when fi rst used. This odour is normal and it is caused by
the initial heating of internal appliance elements and will not occur again.
If your appliance does not emit heat when called for, consult the "operation" section of this manual for further
information.
Use with a CSA or UL certifi ed surge protector.
Do not route the power cord directly underneath the appliance.
This electric appliance meets the construction and safety standards of H.U.D. for application in manufactured
homes when installed according to these instructions.
As with most electronic devices, your new electric appliance has been designed to operate at temperatures
between 5°C (41°F) and 35° C (95°F). During the colder winter months, allow the appliance to reach room
temperature before turning it on.
1.4

unpacking and testing appliance

Carefully remove the appliance from the box. Prior to installing the appliance, remove all packaging material and
test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located
120V, 15 Amp minimum grounded outlet.
note:
The appliance is factory wired for 120 volt power supply. If 240 volt operation is required (see "240V hard wiring
installation" section).
6
W415-2165 / G / 08.15.18
Model No.
NEFB33H
33" Electric
Description
Appliance
120/240V
Voltage
1325/2650W
Watts
15 AMP Grounded
Amps
Circuit
Appliance Width
(86.4cm)
Appliance Height
28 3/4"
(73cm)
9 3/4"
Appliance Depth
(24.8cm)
Net Weight
59lbs (27kg)
Gross Weight
74 lbs (33kg)
NEFB40H
40" Electric
Appliance
120/240V
1325/2650W
15 AMP Grounded
Circuit
34"
40 3/8"
(102.5cm)
32"
(81.2cm)
14"
(35.6cm)
82 lbs (37kg)
101 lbs (46kg)
4.6A

Publicité