Technical Specifications; Electrical Connections - FALMEC ARARX36I5SG Livret D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

B

TECHNICAL SPECIFICATIONS

The technical data pertaining to the electric appliance The technical specifica-
tions of the appliance are shown on the rating plates located inside the range
hood.
C
INSTALLATION
(Section reserved for qualified installers of the range hood)
Minimum distance: distance between the main top of the cooking appliance
and the bottom-most section of the hood. When the hood is positioned above
a gas appliance this minimum distance must be at least 65 cm (25,6") (see fig.
C) or more importantly, check the distances specified for the gas cooking ap-
pliance.
In the outside exhaust version, the diameter of the entire duct run must be no
smaller than the range hood connection.
In the horizontal duct run, the duct must slope slightly (around 10%) upwards,
so as to better ventilate the air outside of the room.
Avoid using angled pipes/elbows where possible. To optimize performance,
keep the duct run as straight and short as possible. Galvanized metal ducting
is recommended.
Comply with the current regulations on air discharge into the atmosphere.
If a boiler, stove, fireplace, etc. that uses gas or other fuels is being used at the
same time, make sure the room where the fumes are extracted is well venti-
lated, in compliance with the current regulations.
Mounting instruction: see section "O" of the booklet.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from
the mains power supply.
Check that the wires inside the range hood are not disconnected or cut; if this
is the case, contact your nearest service centre. The electrical connections must
be performed by qualified personnel.
The connections must be performed in compliance with the legal standards in
force. Check that the receptacle and wiring are able to support the load of the
appliance (see the technical specifications in point B).
THIS APPLIANCE MUST BE GROUNDED.
Important: The hood comes equipped with a 5 ft(1.5 m) power cord with a
NEMA 5-15 molded plug for connection to a 120 VAC, 60 Hz, 15 A power outlet.
This outlet must be located in the duct cover area above the hood.
Some types of appliance are supplied with a cable without plug; in this case,
"standardised" or a junction box must be used, keeping in mind that:
- the yellow/green wire must be used for the earth,
- the blue/white wire must be used for the neutral,
- the brown/black wire must be used for the phase; the cable must not come
5
5

Publicité

Table des Matières
loading

Table des Matières