Never cook on "open" flames under the range hood.
Check deep-fryers during use: superheated oil may be flammable.
- Ensure there is adequate ventilation of the room when the rangehood is used
at the same time as appliances burning gas or other fuels.
- Do not flambe under the rangehood
- The exhaust air must not be discharged into a flue which is used for exhaust-
ing fumes from appliances burning gas or other fuels.
- Ensure that all regulations concerning the discharge of exhaust air have been
fulfilled before you use the appliance.
Before performing any cleaning or maintenance operations, disconnect the ap-
pliance by unplugging it or using the main switch. The manufacturer disclaims
all liability for any damage that may be directly or indirectly caused to people,
things and animals due to the failure to follow all the instructions provided in
this booklet and above all the warnings relating to the installation, operation
and maintenance of the appliance.
N
WARRANTY
The new equipment is covered by warranty.
The warranty conditions are provided by the distributor.
The manufacturer is not liable for any inaccuracies in this booklet resulting
from printing or transcription errors. The manufacturer reserves the right to
modify its products as it considers necessary or in the interests of the user,
without compromising their essential safety and operating characteristics.
O
INSTALLATION OF ISLAND HOOD
WITH LATTICE-WORK
Step 1
- Identify the desired height (H1=65 - 25,6") for the positioning of the hood.
- Slide the lattice-works (C) and (C1) to the desired height (H2), then block them
with the 8 self-threading screws (V2) (Fig.O1a).
- Fasten the lattice-work (C) to the ceiling using the four Ø 8 expansion plugs
and relative screws(V1) (Fig. O1b).
Step 2
- Insert the extension on the flue and fasten them to each other with masking
tape (Fig. O2).
- Fasten the flue-extension assembly (D+E) to the lattice-work (C) with the 4
M4 metric screws (V3) inserted in the existing holes without tightening them
completely (Fig. O2).
- For suction version: identify the optimal height for the rigid or flexible exhaust
pipe (F) and connect it to the motor connection.
Step 3
- Raise the hood, hooking it onto the 4 M5 metric screws (V4) pre-tightened to
the lattice-work (C) (center the Ø11 holes on the slot of the inner liner and move
it laterally)(Fig. O3a).
- Completely tighten the 4 M5 screws (V4) (Fig. O3b).
- Remove the masking tape (Fig. O3c), remove the four M4 metric screws (V3)
previously tightened onto the lattice-work (Fig. O3d) and slide the flue-exten-
12