sion assembly downwards. (Fig. O3e).
- Connect the pipe to the connection of the ceiling discharge hole. (Fig. O3f).
- Make electrical connections only after having removed electrical power sup-
ply.
- Fasten the extension to the lattice-work (C) by means of the 4 M4 metric
screws(V3), without tightening them completely(Fig. O3g).
- Block the extension completely to the lattice-work (C) by screwing down the 4
M4 metric screws (V3).
- Block the flue with the 2 self-threading screws (V5) (Fig. O3i).
- Use the extension support elements(A) (Fig. O2) only if the upper lattice-work is
not used, or in the case of a false ceiling.
13