Safety information
Before replacing the cutting wire the device must be disconnected from the power socket!
Only use special STORCH replacement cutting wire (d = 0.7 mm), art. no. 57 00 28 for the base device and
57 00 29 for the corner cutter. The use of other wires can damage the device, the transformer and result in
subsequent damage.
When connected to the power supply the transformer generates heat, even when the device is switched off.
Make sure that this heat can be emitted freely and that it does not affect any heat-sensitive objects, other-
wise these could be turned into a potential source of danger.
The device should only be used if it can be operated safely. When used on scaffolds, the device should only
be positioned towards the inside of the scaffold: Mounting at the backrests or on the stand, leant against
the house wall. After hanging into the upper rod of the backrest positively fix the clamping bar at the rod
and tighten the Tommy screw.
If it is not possible to secure the device, or the lower section of the backrest is missing, the device should
not be operated at the scaffold railing! In this case use the separate stand with the function of leaning
against the house wall. For this, only the space between the wall and the scaffold board is used.
After installing the device at the designated location make sure that it is stable.
Using the device on the stand with freestanding support is not appropriate for operation on the scaffolding
bay, and only for usage e. g. on the floor in front of the scaffold or on balcony spaces.
If an installed device is left unattended, protect it against external influences and unauthorised use. Remo-
ve the mains plug. The operator of the device is responsible for making sure that any sources of danger and
potential tripping hazards in the vicinity of the device are eliminated (e.g. unsecured power cables, packa-
ging, etc.).

Faults, troubleshooting

A regular and careful cleaning and maintenance schedule is required to ensure trouble-free operation. The
transformer should be disconnected from the socket during troubleshooting measures. Remove the mains
plug!
If the wire does not heat up, check the 230 V power supply. With correct power supply a control lamp is illuminated
at the transformer. Check whether the overload switch at the transformer has triggered and reset it by pushing in.
Attention: If the switch triggers again, do not fix it e. g. with adhesive tape. This will lead to serious device damage.
If this does not resolve the malfunction, contact the STORCH service department or one of the STORCH service cen-
tres in your area. Do not attempt to repair the transformer yourself and do not replace it with a type not approved by
STORCH. Other malfunctions that require the device to be repaired may only be performed by qualified STORCH per-
sonnel or one of the authorised STORCH service centres.

Personnel qualification

The device should only be assembled, commissioned, operated, maintained and cleaned by those persons
who are authorised, qualified and trained to do so.

Spare parts, consumables

All of the device components are available from STORCH and its distribution partners. We recommend that you keep
sufficient quantities of the original cutting wire (d=0.7 mm) (art. no. 57 00 28 and 57 00 29 in stock.
Translation of the original instruction
76

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

57 00 80

Table des Matières