62
AVENTICS | AV03/05 with IO-Link | R412018145–BAL–001–AC
Conversion of the Valve System
1
Fig. 7:
Bridge card
1 IO-Link interface
2 IO-Link interface multipole board
10.2.5
Possible combinations of base plates and cards
The IO-Link interface multipole board is always combined with two 3x base plates.
4x multipole boards are always combined with 2x base plates.
Table 10 shows the possible combinations of base plates, pneumatic supply plates, electrical supply
plates, and transition plates with various multipole boards, bridge cards, and supply plates.
Table 10:
Possible combinations of plates and cards
Base plate
Base plate, 2x
Base plate, 2x
Two base plates, 3x
Two base plates, 2x
Pneumatic supply plate
1)
Two base plates are connected to one multipole board.
10.3 Identifying the modules
10.3.1
Part number for valve system
The part number for the complete valve system (16) is printed on the right end plate. You can use
this part number to reorder an identically configured valve system.
Note that, after a valve system conversion, the part number still refers to the original
configuration (see "10.4.5 Conversion documentation" on page 66).
10.3.2
Address table for PLC configuration
For PLC configuration, you need the address table corresponding to your configuration. The number
16
of the address table for your IO-Link interface can be found on the rating plate on the right end plate.
Note that, after a valve system conversion, the address table still refers to the original
configuration (see "10.4.5 Conversion documentation" on page 66).
2
11
AES-
IOLINK-
24DO
AV03-B
IO-Link
P
6
15
P
6 Pneumatic supply plate
11 Base plate, 3x
15 Bridge card
Circuit boards
Multipole board, 2x
Multipole board, 3x
IO-Link interface multipole board
1)
Multipole board, 4x
Bridge card