General Instructions on Equipment
and Product Damage
Disconnecting plugs while under voltage damages the electronic components of the valve
system!
Large differences in potential occur when disconnecting plugs under voltage, which can destroy
the valve system.
Make sure the relevant system component is not under voltage before assembling the valve
system or when connecting and disconnecting plugs.
Communication malfunctions due to incorrect or insufficient grounding!
Connected components receive incorrect or no signals.
Make sure that the ground connections of all valve system components are linked
to each other
and to ground
with electrically conductive connections.
Malfunctions in the fieldbus communication due improperly laid communication lines!
Connected components receive incorrect or no signals.
Lay the communication lines within buildings. If you lay the communication lines outside
of buildings, the lines laid outside must not exceed 42 m.
The valve system contains electronic components that are sensitive to electrostatic discharge
(ESD)!
If the electrical components are touched by persons or objects, this may lead to an electrostatic
discharge that could damage or destroy the components of the valve system.
Ground the components to prevent electrostatic charging of the valve system.
Use wrist and shoe grounding straps, if necessary, when working on the valve system.
AVENTICS | AV03/05 with IO-Link | R412018145–BAL–001–AC

General Instructions on Equipment and Product Damage

NOTICE
49