Configuration of the AV Valve System

5
Configuration of the AV Valve System
For the IO-Link interface to correctly exchange data from the valve system with the PLC, the IO-Link
master must be able to detect the valve system structure. For this purpose, the electrical component
must be integrated into the IO-Link master. This process is known as IO-Link configuration.
Configuration error!
An incorrect valve system configuration can cause malfunctions in and damage to the overall
system.
The configuration may therefore only be carried out by qualified personnel
(see "2.4 Personnel qualifications" on page 47).
Observe the specifications of the system owner as well as any restrictions resulting from the
overall system.
Observe the documentation of your configuration program.
You may configure the valve system on your computer without the need to connect the unit. The
data can be transferred to the system at a later time on site.
5.1

Loading device master data

The IODD files for the series AES IO-Link interface with English and German language content
are located on the CD R412018133.
If you use a version V1.0.1 IO-Link master, you must use the file " ...IODD1.0.1.xml";
for a version V1.1 master, the file named " ...IODD1.1.xml" must be used.
The files apply to both type A and type B. The files can also be downloaded online from the AVENTICS
Media Directory.
To configure the valve system IO-Link, copy the IODD data files on CD R412018133 to the
computer containing the configuration program.
You can use configuration software from various manufacturers for the IO-Link configuration. The
descriptions in the following sections therefore focus on the basic procedure for configuration.
5.2

Configuring the IO-Link interface in the IO-Link system

Before you can use the IO-Link interface, it has to be recognized by the IO-Link master. This process
is either automatic or must be completed manually. Please observe the documentation for the
IO-Link master used. Since the IO-Link interface does not require changeable parameters, further
configuration is not necessary. The configuration can be transferred directly to the superordinate
controller and the IO-Link interface can begin operation.
5.3

Configuring the valve system

The valve system does not have to be configured. The data is set to a fixed length of 3 byes (24 bits).