Table 8:
Status of the LEDs on commissioning
Designation
Color
State
DIAG (4)
Green
Flashing/
illuminated
If the diagnostic run is successful, you may commission the valve system. Otherwise, the errors
must be remedied (see "Troubleshooting" on page 67).
2. Send payload data to the IO-Link interface.
The valve coils and thus the corresponding LEDs are not actively actuated until the data has been
set to valid by the IO-Link master.
3. Switch on the compressed air supply.
AVENTICS | AV03/05 with IO-Link | R412018145–BAL–001–AC
Commissioning the Valve System with IO-Link
Meaning
The electronics and valve supply voltage is greater than the
lower tolerance limit (21.6 V DC).
55