10.4.2
Permissible configurations
P
A
B
You can expand the valve system at all points labeled with an arrow as long as you do not exceed
the maximum number of 24 solenoid coils:
After the minimal configuration (A)
After a pneumatic supply plate (B) except for the first
After a multipole plate (C)
At the end of a section (D)
At the end of the valve system (E)
To simplify your documentation and configuration, we recommend that you expand the valve
system on the right end (E).
10.4.3
Impermissible configurations
Figure 11 displays the configurations that are not permissible. You may not:
Mount more than 24 solenoid coils (A)
Separate within the minimal configuration (B)
Separate within 4x or 3x multipole plates (C)
Occupy fewer than 6 valve positions (D)
Occupy 7 valve positions (E)